Your browser doesn't support javascript.
loading
Reproducibility of a ramping protocol to measure cerebral vascular reactivity using functional magnetic resonance imaging.
Evanoff, Nicholas G; Mueller, Bryon A; Marlatt, Kara L; Geijer, Justin R; Lim, Kelvin O; Dengel, Donald R.
Afiliação
  • Evanoff NG; School of Kinesiology, University of Minnesota, Minneapolis, Minnesota.
  • Mueller BA; Department of Psychiatry, University of Minnesota, Minneapolis, Minnesota.
  • Marlatt KL; Pennington Biomedical Research Center, Baton Rouge, Louisiana.
  • Geijer JR; Department of Health, Exercise and Rehabilitative Sciences, Winona State University, Winona, Minnesota.
  • Lim KO; Department of Psychiatry, University of Minnesota, Minneapolis, Minnesota.
  • Dengel DR; School of Kinesiology, University of Minnesota, Minneapolis, Minnesota.
Clin Physiol Funct Imaging ; 40(3): 183-189, 2020 May.
Article em En | MEDLINE | ID: mdl-31984617
ABSTRACT
Though individual differences in arterial carbon dioxide and oxygen levels inherently exist, the degree of their influence on cerebral vascular reactivity (CVR) is less clear. We examined the reproducibility of BOLD signal changes to an iso-oxic ramping Pet CO2 protocol. CVR changes were induced by altering Pet CO2 while holding Pet O2 constant using a computer-controlled sequential gas delivery (SGD) device. Two MRI scans, each including a linear change in Pet CO2 , were performed using a 3-Tesla (3T) scanner. This ramp sequence consisted of 1 min at 30 mmHg followed by 4 min period during where Pet CO2 was linearly increased from 30 to 50 mmHg, 1 min at 51 mmHg, and concluded with 4 min at baseline. The protocol was repeated at a separate visit with 3 days between visits (minimum). Intraclass correlation coefficients (ICC) and coefficients of variation (CV) were used to verify reproducibility. Eleven subjects (6 females; mean age 26.5 ± 5.7 years) completed the full testing protocol. Good reproducibility was observed for the within-visit ramp sequence (Visit 1 ICC = 0.82, CV = 6.5%; Visit 2 ICC = 0.74, CV = 6.4%). Similarly, ramp sequence were reproducible between visits (Scan 1 ICC = 0.74, CV = 6.5%; Scan 2 ICC = 0.66, CV = 6.1%). Establishing reproducible methodologies for measuring BOLD signal changes in response to Pet CO2 alterations using a ramp protocol will allow researchers to study CVR functionality. Finally, adding a ramping protocol to CVR studies could provide information about changes in CVR over a broad range of Pet CO2 .
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Imageamento por Ressonância Magnética / Circulação Cerebrovascular Limite: Adult / Female / Humans / Male Idioma: En Revista: Clin Physiol Funct Imaging Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Imageamento por Ressonância Magnética / Circulação Cerebrovascular Limite: Adult / Female / Humans / Male Idioma: En Revista: Clin Physiol Funct Imaging Ano de publicação: 2020 Tipo de documento: Article