Your browser doesn't support javascript.
loading
Highly selective fluorimetric and colorimetric sensing of mercury(II) by exploiting the self-assembly-induced emission of 4-chlorothiophenol capped copper nanoclusters.
Wang, Hai-Bo; Bai, Hong-Yu; Wang, Ya-Shu; Gan, Tian; Liu, Yan-Ming.
Afiliação
  • Wang HB; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang, 464000, People's Republic of China. wanghaibohn@163.com.
  • Bai HY; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang, 464000, People's Republic of China.
  • Wang YS; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang, 464000, People's Republic of China.
  • Gan T; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang, 464000, People's Republic of China. gantianxynu@163.com.
  • Liu YM; College of Chemistry and Chemical Engineering, Institute for Conservation and Utilization of Agro-bioresources in Dabie Mountains, Xinyang Normal University, Xinyang, 464000, People's Republic of China.
Mikrochim Acta ; 187(3): 185, 2020 02 22.
Article em En | MEDLINE | ID: mdl-32088766
ABSTRACT
A highly stable copper nanoclusters (CuNC) carrying 4-chlorothiophenol as a protective ligand is described. They display self-assembly-induced emission with excitation/emission maxima at 330/605 nm even in neutral or alkaline aqueous environment. The fluorescence of these CuNC is quenched by Hg(II). Quenching is mainly ascribed to the formation of a complex formed via Hg-S bonding between the Hg(II) ions and the ligand. This destroys the ordered architectures of the assembled CuNC. The assay enables Hg(II) to be determined with good sensitivity and a linear response ranging from 1 to 500 nM Hg(II) with a 0.3 nM limit of detection. In addition, the method was implemented in a test strip (which undergoes a color change from red to blue) that can be used for visual determination of Hg(II) in complex environmental water samples. Graphical abstractNovel and highly selective fluorimetric and colorimetric methods have been designed for mercury(II) ions determination based on stable self-assembly-induced emission of copper nanoclusters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colorimetria / Cobre / Nanopartículas Metálicas / Fluorometria / Mercúrio Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colorimetria / Cobre / Nanopartículas Metálicas / Fluorometria / Mercúrio Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2020 Tipo de documento: Article