Stereolithographic Surgical Guide with a Combination of Tooth and Bone Support: Accuracy of Guided Implant Surgery in Distal Extension Situation.
Lin, Chia-Cheng; Ishikawa, Masahiro; Maida, Takeo; Cheng, Hsin-Chung; Ou, Keng-Liang; Nezu, Takashi; Endo, Kazuhiko.
Afiliação
  • Lin CC; Division of Biomaterials and Bioengineering, School of Dentistry, Health Sciences University of Hokkaido, Hokkaido 061-0293, Japan.
  • Ishikawa M; School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan.
  • Maida T; Department of Dentistry, Shin Kong Wu Ho-Su Memorial Hospital, Taipei 111, Taiwan.
  • Cheng HC; Division of Oral and Maxillofacial Surgery, Department of Human Biology and Pathophysiology, Health Sciences University of Hokkaido, Hokkaido 002-8072, Japan.
  • Ou KL; Division of Advanced Prosthodontics, Department of Oral Rehabilitation, Health Sciences University of Hokkaido, Hokkaido 002-8072, Japan.
  • Nezu T; School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 110, Taiwan.
  • Endo K; Division of Biomaterials and Bioengineering, School of Dentistry, Health Sciences University of Hokkaido, Hokkaido 061-0293, Japan.
J Clin Med ; 9(3)2020 Mar 05.
Article em En | MEDLINE | ID: mdl-32151043
ABSTRACT
A distal free-end situation could result in insufficient stability of the surgical guide, and could reduce accuracy of the static guided implant surgery (sGIS). The purpose of this study was to investigate the accuracy of sGIS using a combination tooth-and-bone supported stereolithographic (SLA) surgical guide in distal extension situation. Thirty dentists, each placed three implants at the Federal Dentaire Internationale (FDI) teeth positions #46, #47 (a distal extension situation), and #36 (a single tooth gap) via the surgical guide on a model fixed to a manikin. Pre- and post-operative computed tomography (CT) images of the models were superimposed, and the positional and angular deviations of the implants were measured with metrology software. An analysis of variance (ANOVA) test was performed to evaluate the intergroup differences. No significant differences were found for all the positional and angular deviations among the three implant sites, except the bucco-lingual deviation at the implant platform in the #47 position (0.43 ± 0.19 mm) that was significantly larger than the #46 (0.21 ± 0.14 mm) and #36 (0.24 ± 0.25 mm) positions (p < 0.0001). Within the limits of this study, we conclude that, in distal extension situation of missing mandibular molars, adding a bone-supported strut in the distal part of the surgical guide can be beneficial to the accuracy of the sGIS.