Your browser doesn't support javascript.
loading
Stationary tissue background correction increases the precision of clinical evaluation of intra-cardiac shunts by cardiovascular magnetic resonance.
Nickander, Jannike; Lundin, Magnus; Abdula, Goran; Jenner, Jonas; Maret, Eva; Sörensson, Peder; Heiberg, Einar; Sigfridsson, Andreas; Ugander, Martin.
Afiliação
  • Nickander J; Department of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
  • Lundin M; Department of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
  • Abdula G; Department of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
  • Jenner J; Department of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
  • Maret E; Department of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
  • Sörensson P; Department of Medicine, Unit of Cardiology, Karolinska Institutet, and Karolinska University Hospital, Stockholm, Sweden.
  • Heiberg E; Department of Clinical Physiology, Lund University, and Skåne University Hospital, Lund, Sweden.
  • Sigfridsson A; Wallenberg Centre for Molecular Medicine, Lund University, Skåne University Hospital, Lund, Sweden.
  • Ugander M; Department of Clinical Physiology, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden.
Sci Rep ; 10(1): 5053, 2020 03 19.
Article em En | MEDLINE | ID: mdl-32193468
ABSTRACT
We aimed to evaluate the clinical utility of stationary tissue background phase correction for affecting precision in the measurement of Qp/Qs by cardiovascular magnetic resonance (CMR). We enrolled consecutive patients (n = 91) referred for CMR at 1.5T without suspicion of cardiac shunt, and patients (n = 10) with verified cardiac shunts in this retrospective study. All patients underwent phase contrast flow quantification in the ascending aorta and pulmonary trunk. Flow was quantified using two semi-automatic software platforms (SyngoVia VA30, Vendor 1; Segment 2.0R4534, Vendor 2). Measurements were performed both uncorrected and corrected for linear (Vendor 1 and Vendor 2) or quadratic (Vendor 2) background phase. The proportion of patients outside the normal range of Qp/Qs was compared using the McNemar's test. Compared to uncorrected measurements, there were fewer patients with a Qp/Qs outside the normal range following linear correction using Vendor 1 (10% vs 18%, p < 0.001), and Vendor 2 (10% vs 18%, p < 0.001), and following quadratic correction using Vendor 2 (7% vs 18%, p < 0.001). No patient with known shunt was reclassified as normal following stationary background correction. Therefore, we conclude that stationary tissue background correction reduces the number of patients with a Qp/Qs ratio outside the normal range in a consecutive clinical population, while simultaneously not reclassifying any patient with known cardiac shunts as having a normal Qp/Qs. Stationary tissue background correction may be used in clinical patients to increase diagnostic precision.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta / Artéria Pulmonar / Velocidade do Fluxo Sanguíneo / Imageamento por Ressonância Magnética / Doenças Cardiovasculares / Circulação Pulmonar Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta / Artéria Pulmonar / Velocidade do Fluxo Sanguíneo / Imageamento por Ressonância Magnética / Doenças Cardiovasculares / Circulação Pulmonar Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article