Management of a Broken PRECICE Femoral Nail at an Ununited Distraction Osteogenesis Site: A Case Report.
JBJS Case Connect
; 10(1): e0267, 2020.
Article
em En
| MEDLINE
| ID: mdl-32224648
CASE: A 20-year-old man with a history of right lower extremity fibular hemimelia previously treated with PRECICE femoral nail lengthening presented with a broken magnetic nail and a displaced fracture through an ununited distraction osteogenesis site. Using a combination of techniques, we removed the broken implant while maintaining the achieved limb length and preserving the native biology without bone grafting. CONCLUSION: The unique challenges associated with the removal of a broken PRECICE femoral nail are described, with a technique for implant removal that preserves the achieved length, the innate biology of the distraction osteogenesis site, and promoting union without bone grafting.