Your browser doesn't support javascript.
loading
Intact protein quantification in biological samples by liquid chromatography - high-resolution mass spectrometry: somatropin in rat plasma.
Bults, Peter; Sonesson, Anders; Knutsson, Magnus; Bischoff, Rainer; van de Merbel, Nico C.
Afiliação
  • Bults P; Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, the Netherlands; Bioanalytical Laboratory, PRA Health Sciences, Amerikaweg 18, 9407 TK Assen, the Netherlands.
  • Sonesson A; Ferring Pharmaceuticals, Kay Fiskers Plads 11, DK-2300 Copenhagen, Denmark.
  • Knutsson M; Ferring Pharmaceuticals, Kay Fiskers Plads 11, DK-2300 Copenhagen, Denmark.
  • Bischoff R; Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, the Netherlands.
  • van de Merbel NC; Department of Analytical Biochemistry, Groningen Research Institute of Pharmacy, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, the Netherlands; Bioanalytical Laboratory, PRA Health Sciences, Amerikaweg 18, 9407 TK Assen, the Netherlands. Electronic address: MerbelNicovande@prah
Article em En | MEDLINE | ID: mdl-32247186
ABSTRACT
The quantitative determination of intact proteins in biological samples by LC with high-resolution MS detection can be a useful alternative to ligand-binding assays or LC-MS-based quantification of a surrogate peptide after protein digestion. The 22-kDa biopharmaceutical protein somatropin (recombinant human growth hormone) was quantified down to 10 ng/mL (0.45 nM) in 75 µL of rat plasma by the combination of an immunocapture step using an anti-somatropin antibody and LC-MS on a quadrupole-time of flight instrument. Accuracy and precision of the method as well as its selectivity and sensitivity did not depend on the width of the mass extraction window nor on whether only one or a summation of multiple charge states of the protein analyte were used as the detection response. Quantification based on deconvoluted mass spectra showed equally acceptable method performance but with a less favorable lower limit of quantification of 30 ng/mL. Concentrations in plasma after dosing of somatropin to rats correlated well for the deconvolution approach and the quantification based on the summation of the response of the four most intense charge states (14+ to 17+) of somatropin.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas Recombinantes / Hormônio do Crescimento Humano Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteínas Recombinantes / Hormônio do Crescimento Humano Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2020 Tipo de documento: Article