Your browser doesn't support javascript.
loading
Non-invasive Instrument-Based Tests for Quantifying Anterior Chamber Flare in Uveitis: A Systematic Review.
Liu, Xiaoxuan; McNally, Thomas W; Beese, Sophie; Downie, Laura E; Solebo, Ameenat L; Faes, Livia; Husain, Syed; Keane, Pearse A; Moore, David J; Denniston, Alastair K.
Afiliação
  • Liu X; Ophthalmology Department, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • McNally TW; Academic Unit of Ophthalmology, Institute of Inflammation & Ageing, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK.
  • Beese S; Academic Unit of Ophthalmology, Institute of Inflammation & Ageing, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK.
  • Downie LE; Institute of Applied Health Research, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK.
  • Solebo AL; Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Australia.
  • Faes L; Institute of Child Health, University College London, London, UK.
  • Husain S; NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK.
  • Keane PA; Eye Clinic, Cantonal Hospital of Lucerne, Lucerne, Switzerland.
  • Moore DJ; Academic Unit of Ophthalmology, Institute of Inflammation & Ageing, College of Medical and Dental Sciences, University of Birmingham, Birmingham, UK.
  • Denniston AK; NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK.
Ocul Immunol Inflamm ; 29(5): 982-990, 2021 Jul 04.
Article em En | MEDLINE | ID: mdl-32255392
ABSTRACT

Purpose:

Anterior chamber (AC) flare is a key sign for anterior uveitis. New instrument-based techniques for measuring AC flare can offer automation and objectivity. This review aims to identify objective instrument-based measures for AC flare.

Methods:

In this systematic review, we identified studies reporting correlation between instrument-based tests versus clinician AC flare grading, and/or aqueous protein concentration, as well as test reliability.

Results:

Four index tests were identified in 11 studies laser-flare photometry (LFP), optical coherence tomography, ocular flare analysis meter (OFAM) and the double-pass technique. The correlation between LFP and clinician grading was 0.40-0.93 and 0.87-0.94 for LFP and protein concentration. The double-pass technique showed no correlation with clinician grading and insufficient information was available for OFAM.

Conclusion:

LFP shows moderate to strong correlation with clinician grading and aqueous protein concentration. LFP could be a superior reference test compared to clinician AC flare grading for validating new index tests.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Humor Aquoso / Uveíte Anterior / Técnicas de Diagnóstico Oftalmológico / Proteínas do Olho / Câmara Anterior Tipo de estudo: Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: Ocul Immunol Inflamm Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Humor Aquoso / Uveíte Anterior / Técnicas de Diagnóstico Oftalmológico / Proteínas do Olho / Câmara Anterior Tipo de estudo: Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: Ocul Immunol Inflamm Ano de publicação: 2021 Tipo de documento: Article