Your browser doesn't support javascript.
loading
Contrast-enhanced ultrasonography in the initial evaluation of the kidney graft function: a pilot study.
Elec, Florin Ioan; Elec, Alina Daciana; Bolboaca, Sorana; Socaciu, Mihai Adrian; Muntean, Adriana Milena; Iacob, Gheorghița; Moisoiu, Tudor; Zaro, Razvan; Andries, Alexandra-Ioana; Badulescu, Maria Ramona; Ignat, Radu Mihai; Badea, Radu Ion.
Afiliação
  • Elec FI; Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca, Romania; Dpt. of Urology, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania;. ioan.elec@gmail.com.
  • Elec AD; Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca, Romania;. dralinaelec@gmail.com.
  • Bolboaca S; Dpt. of Medical Informatics and Biostatistics, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania. sbolboaca@gmail.com.
  • Socaciu MA; Dpt.of Medical Imaging, Regional Institute of Gastroenterology "Prof. Dr. Octavian Fodor", Cluj-Napoca, Romania; Dpt.of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania;. mihaiaso@gmail.com.
  • Muntean AM; Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca, Romania;. munteana2@yahoo.com.
  • Iacob G; Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca, Romania;. iacob.gheorghita@gmail.com.
  • Moisoiu T; Dpt.of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romaniaș Clinical Institute of Urology and Renal Transplantation, Cluj-Napoca, Romania;. tmoisoiu@gmail.com.
  • Zaro R; Dpt.of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania. razvanzaro@yahoo.com.
  • Andries AI; Dpt.of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania;. alexandra.andries.ioana@gmail.com.
  • Badulescu MR; Dpt. of Urology, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania. ramona.contis@gmail.com.
  • Ignat RM; Dpt.of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania; Dpt.of Anatomy, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania;. radu.mihai.ignat@gmail.com.
  • Badea RI; Dpt.of Medical Imaging, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania; Dpt.of Medical Imaging, Regional Institute of Gastroenterology "Prof. Dr. Octavian Fodor", Cluj-Napoca, Romania;. rbadea2012@gmail.com.
Med Ultrason ; 22(3): 272-278, 2020 Sep 05.
Article em En | MEDLINE | ID: mdl-32399535
ABSTRACT

AIM:

Our study aimed to assess the usefulness of contrast-enhanced ultrasound (CEUS) in the initial evaluation of the graft function. MATERIALS AND

METHOD:

A cross-sectional study was conducted in the early postoperative period on patients with kidney transplantation, between September 2017 to November 2018. Two groups of patients were investigated; delayed graft function (DGF) and early graft function (EGF). All patients were examined by grey scale, Doppler ultrasound and CEUS.

RESULTS:

Nineteen patients, aged from 23 to 64 years (mean age 50 years), 7 in the DGF group and 12 in the EGF group were evaluated. The resistive index (RI) show significantly higher values in the DGF group at the level of upper interlobar artery (p=0.025) and medium interlobar artery (p=0.02). The CEUS investigation shows a greater region of interest (ROI) area (p=0.02) and lower values for wash-out area under the curve (WoAUC) (p=0.047) and respectively wash-in and wash-out area under the curve (WiWoAUC) (p=0.031) for the DGF group. The quality of fit (QoF) proved lower in the DGF group either for evaluation of global graft (p=0.012), cortex (p=0.025), or medulla (p=0.009).A significant relationship among all patients was found between the glomerular filtration rate (GFR) [ml/min] and the renal artery fall time (FT) [s] (p=0.012), WoAUC [a.u.] (p=0.03), and WiWoAUC [a.u.] (p=0.024). The arterial QoF [%] was associated with the arterial ROI area (p=0.048).

CONCLUSIONS:

Intensity CEUS parameters WoAUC and WiWoAUC may be useful to diagnose and follow-up grafts with delayed function. Additional studies on larger cohorts are required for the recommendation of CEUS as a routine evaluation of the transplanted kidney.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cuidados Pós-Operatórios / Aumento da Imagem / Ultrassonografia / Transplante de Rim / Meios de Contraste / Rim Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Med Ultrason Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cuidados Pós-Operatórios / Aumento da Imagem / Ultrassonografia / Transplante de Rim / Meios de Contraste / Rim Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Med Ultrason Ano de publicação: 2020 Tipo de documento: Article