Your browser doesn't support javascript.
loading
Resolving the relative contributions of cistern and pour flushing to toilet water usage: Measurements from urban test sites in India.
Welling, Claire M; Varigala, Siva; Krishnaswamy, Srinivas; Raj, Antony; Lynch, Brendon; Piascik, Jeffrey R; Stoner, Brian R; Hawkins, Brian T; Hegarty-Craver, Meghan; Luettgen, Michael J; Grego, Sonia.
Afiliação
  • Welling CM; Center for WaSH-AID, Dept. of Electrical and Computer Engineering, Duke University, Durham, NC 27701, USA.
  • Varigala S; Dept. Chem. Engineering, BITS Pilani K.K. Birla Goa Campus, Goa, India; ITC-Kohler Co., Pune, Maharashtra, India.
  • Krishnaswamy S; Dept. Chem. Engineering, BITS Pilani K.K. Birla Goa Campus, Goa, India.
  • Raj A; RTI India, New Delhi 110 092, India.
  • Lynch B; Biomass Controls, Durham, NC 27701, USA.
  • Piascik JR; Biomass Controls, Durham, NC 27701, USA.
  • Stoner BR; Center for WaSH-AID, Dept. of Electrical and Computer Engineering, Duke University, Durham, NC 27701, USA.
  • Hawkins BT; Center for WaSH-AID, Dept. of Electrical and Computer Engineering, Duke University, Durham, NC 27701, USA.
  • Hegarty-Craver M; RTI International, Research Triangle Park, NC 27709, USA.
  • Luettgen MJ; Kohler Co., Kohler, WI 53044, USA.
  • Grego S; Center for WaSH-AID, Dept. of Electrical and Computer Engineering, Duke University, Durham, NC 27701, USA; RTI International, Research Triangle Park, NC 27709, USA. Electronic address: sonia.grego@duke.edu.
Sci Total Environ ; 730: 138957, 2020 Aug 15.
Article em En | MEDLINE | ID: mdl-32402964
ABSTRACT
A challenge in water reuse for toilet flushing in India and other Asian countries derives from pour flushing practices. It is a common assumption that the amount of pour flushed water used for personal cleansing is small in comparison to the cistern flush volume, however there is a knowledge gap regarding the actual contribution of each water source to the blackwater amount. In this study, digital water meters were used to measure the fraction of water from personal wash tap relative to cistern water that is used for toilet flushing. High temporal resolution measurements were carried in three different urban sites in the city of Coimbatore in the southern Indian state of Tamil Nadu where onsite sanitation treatment prototypes that may provide reclaimed water for cistern flushing are being tested. Data collected over periods of up to 2 months show that the contribution of the cistern flush to the total blackwater volume is low (14-40%). These data highlight an important factor to inform interventions designed around water reuse for flushing in world geographies where personal toilet cleansing by water is the common practice.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Total Environ Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Total Environ Ano de publicação: 2020 Tipo de documento: Article