Orthokeratology with increased compression factor (OKIC): study design and preliminary results.
Wan, Kin; Lau, Jason Ki-Kit; Cheung, Sin Wan; Cho, Pauline.
Afiliação
  • Wan K; School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China.
  • Lau JK; School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China.
  • Cheung SW; School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China.
  • Cho P; School of Optometry, The Hong Kong Polytechnic University, Hong Kong, China.
BMJ Open Ophthalmol ; 5(1): e000345, 2020.
Article em En | MEDLINE | ID: mdl-32420450
ABSTRACT

OBJECTIVE:

To present the study design and the baseline data of a prospective cohort study investigating the safety, refractive correction and effectiveness of myopia control in subjects fitted with orthokeratology (ortho-k) lenses of different compression factors. METHODS AND

ANALYSIS:

This study is a 2-year longitudinal, double-masked, partially randomised study. Myopic children aged between 6 and 10 years are recruited and they may choose to participate in either the ortho-k or spectacle-wearing group. Subjects in the ortho-k group are randomly assigned to wear ortho-k lenses of either conventional compression factor (CCF, 0.75 D) or increased compression factor (ICF, 1.75 D). For the ortho-k subjects, the time and between-group effects within the first month of lens wear were analysed.

RESULTS:

Sixty-nine ortho-k subjects (CCF 34; ICF 35) and 30 control subjects were recruited. There were no significant differences in baseline demographic data among the three groups of subjects (p>0.19). At the 1-month visit, the first fit success rates were 97% and 100% in the CCF and ICF ortho-k group, respectively. A higher percentage of ICF subjects could achieve full correction (CCF 88.2%; ICF 94.3%). The change in axial length was significantly higher in the ICF group (CCF, 0.003 mm; ICF, -0.031 mm) (p<0.05). No significant between-group differences in daytime vision or in the coverage and depth of corneal staining between the two ortho-k groups (p>0.05) were observed at any visit.

CONCLUSION:

ICF did not compromise the corneal integrity and the lens centration within the first month of lens wear. The preliminary performance of ortho-k lenses with ICF of 1.00D shows that it was safe to be used in the longer term for the investigation of myopia control. TRIAL REGISTRATION NUMBER NCT02643342.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: BMJ Open Ophthalmol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: BMJ Open Ophthalmol Ano de publicação: 2020 Tipo de documento: Article