Normalization of wastewater coagulation-flocculation trials and implications in terms of variability in treatment performance and comparison of commercial coagulants.
Environ Technol
; 42(25): 4015-4026, 2021 Nov.
Article
em En
| MEDLINE
| ID: mdl-32421400
Normalizations by TSS or P-PO43- initial concentrations are consistent as they are correlated to the Jar-test performances. Jar-tests results are independent of the wastewater quality variations in terms of TSS and P-PO43- and independent of the WWTP origin of the water. A notable variability in the TSS results indicates that the pollutant's initial load has to be taken into account even with normalizations. This variability is lower with normalization by P-PO43-, indicating that this is the best indicator to consider. It is possible to determine that the optimal cation dosage is 60â
mol Fe3+ / kg P-PO43- as it guarantees a residual concentration of 0.7-1.0 mgP/L and a good removal of TSS.Then, six commercially available cationic coagulants were compared, demonstrating a comparable effect at a comparable normalized molar dose, whatever the coagulant on both TSS and P-PO43-, as well as on soluble carbon and nitrogen. The differences observed between these types of coagulants in the literature are then probably due to methodological issues. Settling velocity distribution charts were also very similar for the different coagulants. This confirms that the source of cation and the type of cation have no significant effect on physico-chemical settling performances.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Contexto em Saúde:
2_ODS3
Base de dados:
MEDLINE
Assunto principal:
Purificação da Água
/
Águas Residuárias
Idioma:
En
Revista:
Environ Technol
Ano de publicação:
2021
Tipo de documento:
Article