ABSTRACT

AIM:

To review the use of clinical corneal sealants for the closure of full thickness corneal wounds.

METHODS:

A systematic review was conducted across CENTRAL, Medline, PubMed, Embase, Scopus, mRCT and ICTRP for the keywords of 'cornea', 'full-thickness wound', 'sealant' and their synonyms. Only evidence level 2 of higher as graded by Oxford Centre of Evidence-based Medicine were included for this review.

RESULTS:

Seven studies were included; three randomized controlled trials investigated ReSure® sealant, 2 OcuSeal®, 1 human fibrin glue vs cyanoacrylate and 1 human fibrin glue as an adjunct to sutures vs sutures alone in penetrating keratoplasty. ReSure® was superior to suture for sealing leaking corneal incisions after cataract surgery despite provocation. ReSure® sealant has not been tested on complex full thickness corneal wounds, perforated ulcers or penetrating keratoplasty. OcuSeal® was also able to seal full thickness cornea wound post-cataract surgery to prevent ingress of Trypan blue dye. Human fibrin glue and cyanoacrylate were similarly effective in treating corneal perforations <3 mm of mixed etiologies.

CONCLUSION:

There are limited high-level evidence for corneal sealants. The currently available sealants with human data are ReSure®, OcuSeal®, human fibrin glue and cyanoacrylates. While ReSure® and OcuSeal® are effective post-cataract surgery, there are no data for perforations from other etiologies. Post-approval data from ReSure® registry report good tolerability and no apparent safety concerns.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Adesivos Teciduais / Lesões da Córnea Tipo de estudo: Clinical_trials / Systematic_reviews Limite: Humans Idioma: En Revista: Curr Eye Res Ano de publicação: 2020 Tipo de documento: Article