Your browser doesn't support javascript.
loading
A resonance Rayleigh scattering and colorimetric dual-channel sensor for sensitive detection of perfluorooctane sulfonate based on toluidine blue.
He, Jincan; Qiu, Peipei; Song, Jiayi; Zhang, Shiyun; Bai, Yan.
Afiliação
  • He J; Guangdong Provincial Engineering Research Center of Public Health Detection and Assessment, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, Guangdong, China. hejincan300@163.com.
  • Qiu P; Guangdong Provincial Engineering Research Center of Public Health Detection and Assessment, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, Guangdong, China.
  • Song J; Guangdong Provincial Engineering Research Center of Public Health Detection and Assessment, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, Guangdong, China.
  • Zhang S; Guangdong Provincial Engineering Research Center of Public Health Detection and Assessment, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, Guangdong, China.
  • Bai Y; Guangdong Provincial Engineering Research Center of Public Health Detection and Assessment, Guangdong Pharmaceutical University, No. 283 Jianghai Avenue, Haizhu District, Guangzhou, 510310, Guangdong, China.
Anal Bioanal Chem ; 412(22): 5329-5339, 2020 Sep.
Article em En | MEDLINE | ID: mdl-32613567
ABSTRACT
This work described the use of a basic phenothiazine dye (toluidine blue, TB) as a resonance Rayleigh scattering (RRS) and colorimetric probe for the detection of perfluorooctane sulfonate (PFOS). Owing to the electrostatic interactions between TB and PFOS, TB in the presence of PFOS caused great enhancement of RRS signal at dual-wavelength (I345 nm and I506 nm) and the ratio changes of absorbance (A502 nm/A630 nm). The RRS enhancement was attributed to the absorption-rescattering resonance effect, the increase of the molecular size, and the enhancement of hydrophobicity. The analytical procedure was implemented by physically mixing TB, Britton-Robinson buffer solution, and PFOS solution (or sample solution) all-in-one, avoiding the tedious pre-derivatization or the preparation of nanoparticles. The whole approach was less than 8 min. Under the optimal conditions, the analytical performance was acquired. The linear ranges for RRS and colorimetry were 0.04-8.0 and 1.0-20 µmol/L, with detection limits of 4.2 nmol/L and 112 nmol/L, respectively. The RRS method was applied to the determination of PFOS in environmental water with recoveries of 93.2-106%. The dual-channel sensor is convenient, rapidly responsive, sensitive, and cost-effective, integrating the advantages of RRS and colorimetry. Graphical abstract.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2020 Tipo de documento: Article