Your browser doesn't support javascript.
loading
Quantitative myocardial perfusion 82Rb-PET assessed by hybrid PET/coronary-CT: Normal values and diagnostic performance.
Freitag, Martin T; Bremerich, Jens; Wild, Damian; Haaf, Philip; Zellweger, Michael J; Caobelli, Federico.
Afiliação
  • Freitag MT; Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
  • Bremerich J; Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
  • Wild D; Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland.
  • Haaf P; Clinic of Cardiology, University Hospital Basel, Basel, Switzerland.
  • Zellweger MJ; Clinic of Cardiology, University Hospital Basel, Basel, Switzerland.
  • Caobelli F; Clinic of Radiology and Nuclear Medicine, University Hospital Basel, Petersgraben 4, 4031, Basel, Switzerland. Federico.Caobelli@usb.ch.
J Nucl Cardiol ; 29(2): 464-473, 2022 04.
Article em En | MEDLINE | ID: mdl-32676910
ABSTRACT

PURPOSE:

We aimed to assess normal values for quantified myocardial blood flow (MBF) on a hybrid PET/coronary-CT scanner and to test their diagnostic performance in patients with suspected CAD. MATERIALS AND

METHODS:

Patients underwent 82Rb-PET/CT and integrated CT-based coronary angiography (CCTA) and were classified as normal (no stenosis), with non-obstructive stenosis (< 50%) and with CAD (≥ 50%). Global and regional stress MBF (sMBF), rest MBF and myocardial flow reserve (MFR) were calculated. Ischemia was defined as SDS ≥ 2, severe ischemia as SDS ≥ 7.

RESULTS:

357 consecutive patients were included. Global sMBF and MFR were higher in normal patients than in patients with CAD (3.61 ± 0.71 vs 3.04 ± 0.77, P < 0.0001; 3.08 ± 0.84 vs 2.68 ± 0.79, P = 0.0001), but not different compared to patients with non-obstructive stenosis (3.61 ± 0.71 vs 3.43 ± 0.69, P = 0.052; 3.08 ± 0.84 vs 2.99 ± 0.82, P = 0.45). sMBF yielded superior accuracy over MFR in identifying both ischemia (AUC 0.74 vs 0.62, P = 0.003) and severe ischemia (AUC 0.88 vs 0.78, P = 0.012). Optimal threshold for global sMBF to rule out myocardial ischemia was 3.5 mL g-1 min-1.

CONCLUSIONS:

Normal quantitative values are provided. Global sMBF provided higher diagnostic accuracy than MFR. Using sMBF-threshold of 3.5 mL·g-1·min-1 on 82Rb-PET/CT yielded similar NPV (96%) as CCTA to rule out CAD. Hence, resting scan could be omitted in patients with sMBF values above reference.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Reserva Fracionada de Fluxo Miocárdico / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Nucl Cardiol Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Reserva Fracionada de Fluxo Miocárdico / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Nucl Cardiol Ano de publicação: 2022 Tipo de documento: Article