Your browser doesn't support javascript.
loading
An innovative sampling approach combined with liquid chromatography-tandem mass spectrometry for the analysis of emerging pollutants in drinking water.
Di Carro, Marina; Lluveras-Tenorio, Anna; Benedetti, Barbara; Magi, Emanuele.
Afiliação
  • Di Carro M; Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, Genoa 16146, Italy.
  • Lluveras-Tenorio A; National Interuniversity Consortium of Materials Science and Technology, Via G. Giusti 9, Florence, Italy.
  • Benedetti B; Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, Genoa 16146, Italy.
  • Magi E; Department of Chemistry and Industrial Chemistry, University of Genoa, Via Dodecaneso 31, Genoa 16146, Italy.
J Mass Spectrom ; 55(11): e4608, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32707599
ABSTRACT
In this work, an innovative sampling and preconcentration method followed by analysis with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization (LC-ESI-MS/MS) was developed for the determination of different emerging pollutants (five anti-inflammatory drugs and one antibacterial agent) in water matrices. Thin-film microextraction blades, consisting of stainless steel blades with a coating made of divinylbenzene, have been employed. The blades, fixed onto a stainless steel support, were mounted on a laboratory stirrer with adjustable speed, immersed in water samples and eluted with methanol. The analytical procedure was developed, carefully optimizing stirring speed and extraction time. A good reproducibility among the blades was observed; quantitation limits at the ng L-1 level were achieved. Calibration curves were constructed by applying the whole procedure to tap water samples, free from analytes, spiked with standards in the concentration range 0.01-2 µg L-1 ; good linearity was obtained, with R2 between 0.9984 and 0.9991. The optimized method was applied to tap and surface waters; two anti-inflammatory drugs were detected at the ng L-1 level in surface water. In one sample, diclofenac and naproxen were measured at 26 ± 5 and 15 ± 1 ng L-1 , respectively; only diclofenac was quantified in the other sample at 14 ± 3 ng L-1 .
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Anti-Inflamatórios / Antibacterianos Idioma: En Revista: J Mass Spectrom Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Anti-Inflamatórios / Antibacterianos Idioma: En Revista: J Mass Spectrom Ano de publicação: 2020 Tipo de documento: Article