Your browser doesn't support javascript.
loading
Estimating Global Visual Field Indices in Glaucoma by Combining Macula and Optic Disc OCT Scans Using 3-Dimensional Convolutional Neural Networks.
Yu, Hsin-Hao; Maetschke, Stefan R; Antony, Bhavna J; Ishikawa, Hiroshi; Wollstein, Gadi; Schuman, Joel S; Garnavi, Rahil.
Afiliação
  • Yu HH; IBM Research Australia, Melbourne, Victoria, Australia. Electronic address: hsin-hao.yu@au1.ibm.com.
  • Maetschke SR; IBM Research Australia, Melbourne, Victoria, Australia.
  • Antony BJ; IBM Research Australia, Melbourne, Victoria, Australia.
  • Ishikawa H; Department of Ophthalmology, NYU Langone Health, New York, New York; Department of Biomedical Engineering, NYU Tandon School of Engineering, New York, New York; Center for Neural Science, NYU, New York, New York.
  • Wollstein G; Department of Ophthalmology, NYU Langone Health, New York, New York; Department of Biomedical Engineering, NYU Tandon School of Engineering, New York, New York; Center for Neural Science, NYU, New York, New York.
  • Schuman JS; Department of Ophthalmology, NYU Langone Health, New York, New York; Department of Biomedical Engineering, NYU Tandon School of Engineering, New York, New York; Center for Neural Science, NYU, New York, New York; Department of Physiology and Neuroscience, NYU Langone Health, New York, New York; Depa
  • Garnavi R; IBM Research Australia, Melbourne, Victoria, Australia.
Ophthalmol Glaucoma ; 4(1): 102-112, 2021.
Article em En | MEDLINE | ID: mdl-32826205
ABSTRACT

PURPOSE:

To evaluate the accuracy at which visual field global indices could be estimated from OCT scans of the retina using deep neural networks and to quantify the contributions to the estimates by the macula (MAC) and the optic nerve head (ONH).

DESIGN:

Observational cohort study.

PARTICIPANTS:

A total of 10 370 eyes from 109 healthy patients, 697 glaucoma suspects, and 872 patients with glaucoma over multiple visits (median = 3).

METHODS:

Three-dimensional convolutional neural networks were trained to estimate global visual field indices derived from automated Humphrey perimetry (SITA 24-2) tests (Zeiss, Dublin, CA), using OCT scans centered on MAC, ONH, or both (MAC + ONH) as inputs. MAIN OUTCOME

MEASURES:

Spearman's rank correlation coefficients, Pearson's correlation coefficient, and absolute errors calculated for 2 indices visual field index (VFI) and mean deviation (MD).

RESULTS:

The MAC + ONH achieved 0.76 Spearman's correlation coefficient and 0.87 Pearson's correlation for VFI and MD. Median absolute error was 2.7 for VFI and 1.57 decibels (dB) for MD. Separate MAC or ONH estimates were significantly less correlated and less accurate. Accuracy was dependent on the OCT signal strength and the stage of glaucoma severity.

CONCLUSIONS:

The accuracy of global visual field indices estimate is improved by integrating information from MAC and ONH in advanced glaucoma, suggesting that structural changes of the 2 regions have different time courses in the disease severity spectrum.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disco Óptico / Glaucoma Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Ophthalmol Glaucoma Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Disco Óptico / Glaucoma Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Ophthalmol Glaucoma Ano de publicação: 2021 Tipo de documento: Article