Your browser doesn't support javascript.
loading
Validation of a liquid chromatography tandem mass spectrometry method for the simultaneous determination of hydroxychloroquine and metabolites in human whole blood.
Austin, Donna; John, Catharine; Hunt, Beverley J; Carling, Rachel S.
Afiliação
  • Austin D; Biochemical Sciences, Viapath, Guys & St Thomas' NHSFT, London, UK.
  • John C; Biochemical Sciences, Viapath, Guys & St Thomas' NHSFT, London, UK.
  • Hunt BJ; Thrombosis & Haemophilia Centre, Guy's & St Thomas' NHSFT, London, UK.
  • Carling RS; Biochemical Sciences, Viapath, Guys & St Thomas' NHSFT, London, UK.
Clin Chem Lab Med ; 58(12): 2047-2061, 2020 09 13.
Article em En | MEDLINE | ID: mdl-32915766
ABSTRACT
Objectives Hydroxychloroquine (HCQ) is an anti-malarial and immunomodulatory drug reported to inhibit the Corona virus, SARS-CoV-2, in vitro. At present there is insufficient evidence from clinical trials to determine the safety and efficacy of HCQ as a treatment for COVID-19. However, since the World Health Organisation declared COVID-19 a pandemic in March 2020, the US Food and Drug Administration issued an Emergency Use Authorisation to allow HCQ and Chloroquine (CQ) to be distributed and used for certain hospitalised patients with COVID-19 and numerous clinical trials are underway around the world, including the UK based RECOVERY trial, with over 1000 volunteers. The validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of HCQ and two of its major metabolites, desethylchloroquine (DCQ) and di-desethylchloroquine (DDCQ), in whole blood is described. Methods Blood samples were deproteinised using acetonitrile. HCQ, DCQ and DDCQ were chromatographically separated on a biphenyl column with gradient elution, at a flow rate of 500 µL/min. The analysis time was 8 min. Results For each analyte linear calibration curves were obtained over the concentration range 50-2000 µg/L, the lower limit of quantification (LLOQ) was 13 µg/L, the inter-assay relative standard deviation (RSD) was <10% at 25, 800 and 1750 µg/L and mean recoveries were 80, 81, 78 and 62% for HCQ, d4-HCQ, DCQ and DDCQ, respectively. Conclusion This method has acceptable analytical performance and is applicable to the therapeutic monitoring of HCQ, evaluating the pharmacokinetics of HCQ in COVID-19 patients and supporting clinical trials.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 / 3_ND Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Hidroxicloroquina Limite: Humans Idioma: En Revista: Clin Chem Lab Med Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 / 3_ND Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Hidroxicloroquina Limite: Humans Idioma: En Revista: Clin Chem Lab Med Ano de publicação: 2020 Tipo de documento: Article