Your browser doesn't support javascript.
loading
Phantom-based quality assurance for multicenter quantitative MRI in locally advanced cervical cancer.
van Houdt, Petra J; Kallehauge, Jesper F; Tanderup, Kari; Nout, Remi; Zaletelj, Marko; Tadic, Tony; van Kesteren, Zdenko J; van den Berg, Cornelius A T; Georg, Dietmar; Côté, Jean-Charles; Levesque, Ives R; Swamidas, Jamema; Malinen, Eirik; Telliskivi, Sven; Brynolfsson, Patrik; Mahmood, Faisal; van der Heide, Uulke A.
Afiliação
  • van Houdt PJ; Department of Radiation Oncology, the Netherlands Cancer Institute, Amsterdam, the Netherlands. Electronic address: p.v.houdt@nki.nl.
  • Kallehauge JF; Danish Centre for Particle Therapy, Aarhus, Denmark.
  • Tanderup K; Department of Clinical Medicine, Aarhus University Hospital, Denmark.
  • Nout R; Department of Radiation Oncology, Leiden University Medical Center, the Netherlands.
  • Zaletelj M; Department of Radiotherapy, Institute of Oncology Ljubljana, Slovenia.
  • Tadic T; Radiation Medicine Program, Princess Margaret Cancer Center, Toronto, Canada.
  • van Kesteren ZJ; Department of Radiation Oncology, Amsterdam University Medical Center, the Netherlands.
  • van den Berg CAT; Department of Radiotherapy, University Medical Center Utrecht, the Netherlands.
  • Georg D; Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University Of Vienna, Austria.
  • Côté JC; Department of Radiation Oncology, Centre Hospitalier de l'Universite de Montreal, Canada.
  • Levesque IR; Medical Physics Unit and Gerald Bronfman Department of Oncology, McGill University, Montreal, Canada.
  • Swamidas J; Department of Radiation Oncology, Tata Memorial Centre, Mumbai, India.
  • Malinen E; Department of Medical Physics, Oslo University Hospital, Norway.
  • Telliskivi S; Department of Radiation Oncology, North-Estonia Medical Centre, Tallinn, Estonia.
  • Brynolfsson P; Department of Translational Sciences, Skåne University Hospital, Lund, Sweden.
  • Mahmood F; Department of Oncology, Odense University Hospital, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.
  • van der Heide UA; Department of Radiation Oncology, the Netherlands Cancer Institute, Amsterdam, the Netherlands.
Radiother Oncol ; 153: 114-121, 2020 12.
Article em En | MEDLINE | ID: mdl-32931890
BACKGROUND AND PURPOSE: A wide variation of MRI systems is a challenge in multicenter imaging biomarker studies as it adds variation in quantitative MRI values. The aim of this study was to design and test a quality assurance (QA) framework based on phantom measurements, for the quantitative MRI protocols of a multicenter imaging biomarker trial of locally advanced cervical cancer. MATERIALS AND METHODS: Fifteen institutes participated (five 1.5 T and ten 3 T scanners). Each institute optimized protocols for T2, diffusion-weighted imaging, T1, and dynamic contrast-enhanced (DCE-)MRI according to system possibilities, institutional preferences and study-specific constraints. Calibration phantoms with known values were used for validation. Benchmark protocols, similar on all systems, were used to investigate whether differences resulted from variations in institutional protocols or from system variations. Bias, repeatability (%RC), and reproducibility (%RDC) were determined. Ratios were used for T2 and T1 values. RESULTS: The institutional protocols showed a range in bias of 0.88-0.98 for T2 (median %RC = 1%; %RDC = 12%), -0.007 to 0.029 × 10-3 mm2/s for the apparent diffusion coefficient (median %RC = 3%; %RDC = 18%), and 0.39-1.29 for T1 (median %RC = 1%; %RDC = 33%). For DCE a nonlinear vendor-specific relation was observed between measured and true concentrations with magnitude data, whereas the relation was linear when phase data was used. CONCLUSION: We designed a QA framework for quantitative MRI protocols and demonstrated for a multicenter trial for cervical cancer that measurement of consistent T2 and apparent diffusion coefficient values is feasible despite protocol differences. For DCE-MRI and T1 mapping with the variable flip angle method, this was more challenging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias do Colo do Útero Tipo de estudo: Clinical_trials Limite: Female / Humans Idioma: En Revista: Radiother Oncol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias do Colo do Útero Tipo de estudo: Clinical_trials Limite: Female / Humans Idioma: En Revista: Radiother Oncol Ano de publicação: 2020 Tipo de documento: Article