Your browser doesn't support javascript.
loading
Reduced and standard field-of-view diffusion weighted imaging in patients with rectal cancer at 3 T-Comparison of image quality and apparent diffusion coefficient measurements.
Attenberger, U I; Tavakoli, A; Stocker, D; Stieb, S; Riesterer, O; Turina, M; Schoenberg, S O; Pilz, L; Reiner, C S.
Afiliação
  • Attenberger UI; Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany. Electronic address: ulrike.attenberger@ukbonn.de.
  • Tavakoli A; Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany; Department of Radiology, German Cancer Research Center (DKFZ), Germany. Electronic address: s.tavakoli@gmx.de.
  • Stocker D; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland. Electronic address: daniel.stocker@usz.ch.
  • Stieb S; Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland.
  • Riesterer O; Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland. Electronic address: oliver.riesterer@ksa.ch.
  • Turina M; Department of Surgery and Transplantation, University Hospital Zurich, Zurich, Switzerland. Electronic address: matthias.turina@usz.ch.
  • Schoenberg SO; Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany. Electronic address: stefan.schoenberg@umm.de.
  • Pilz L; Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany. Electronic address: lothar.pilz@medma.uni-heidelberg.de.
  • Reiner CS; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland. Electronic address: caecilia.reiner@usz.ch.
Eur J Radiol ; 131: 109257, 2020 Oct.
Article em En | MEDLINE | ID: mdl-32947092
PURPOSE: To compare a zoomed EPI-DWI (z-EPI) with a standard EPI-DWI (s-EPI) in the primary diagnostics of rectal cancer and assess its potential of reduced image artifacts. METHOD: 22 therapy-naïve patients with rectal cancer underwent rectal MRI at a 3 T-system. The protocols consisted of a z-EPI DWI and s-EPI DWI sequence. Images were assessed by two independent and experienced readers regarding overall image quality and artifacts on a 5-point Likert scale, as well as overall sequence preference. In a lesion-based analysis, tumor and lymph node detection were rated on a 4-point Likert scale. Apparent diffusion coefficient (ADC) measurements were performed. RESULTS: Overall Image quality score for z-EPI and s-EPI showed no statistically significant differences (p = 0.80/0.54, reader 1/2) with a median score of 4 ("good" image quality) for both sequences. The image quality preference rank for z-EPI and s-EPI was given the category 'no preference' in 64 % (reader 1) and 50 % (reader 2). Most artifact-related scores (susceptibility, motion and distortion) did not show reproducible significant differences between z-EPI and s-EPI. The two sequences exhibited comparable, mostly good and excellent quality scores for tumor and lymph node detection (p = 0.19-0.99). ADC values were significantly lower for z-EPI than for s-EPI (p = 0.001/0.002, reader 1/2) with good agreement of ADC measurements between both readers. CONCLUSION: Our data showed comparable image quality and lesion detection for the z-EPI and the s-EPI sequence in MRI of rectal cancer, whereas the mean ADC of the tumor was significantly lower in z-EPI compared to s-EPI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Retais / Imagem Ecoplanar / Imageamento Tridimensional / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Guideline / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Retais / Imagem Ecoplanar / Imageamento Tridimensional / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Guideline / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2020 Tipo de documento: Article