Your browser doesn't support javascript.
loading
Miniaturized Fluorimetric Method for Quantification of Zinc in Dry Dog Food.
Martins, Rute C; Pereira, Ana M; Matos, Elisabete; Barreiros, Luisa; Fonseca, António J M; Cabrita, Ana R J; Segundo, Marcela A.
Afiliação
  • Martins RC; LAQV, REQUIMTE, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua Jorge Viterbo Ferreira no 228, Porto 4050-313, Portugal.
  • Pereira AM; LAQV, REQUIMTE, Instituto de Ciências Biomédicas de Abel Salazar (ICBAS), Universidade do Porto, Rua de Jorge Viterbo Ferreira no 228, Porto 4050-313, Portugal.
  • Matos E; SORGAL, Sociedade de Óleos e Rações S.A., Estrada Nacional 109 Lugar da Pardala, São João 3880-728, Ovar, Portugal.
  • Barreiros L; LAQV, REQUIMTE, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua Jorge Viterbo Ferreira no 228, Porto 4050-313, Portugal.
  • Fonseca AJM; LAQV, REQUIMTE, Instituto de Ciências Biomédicas de Abel Salazar (ICBAS), Universidade do Porto, Rua de Jorge Viterbo Ferreira no 228, Porto 4050-313, Portugal.
  • Cabrita ARJ; LAQV, REQUIMTE, Instituto de Ciências Biomédicas de Abel Salazar (ICBAS), Universidade do Porto, Rua de Jorge Viterbo Ferreira no 228, Porto 4050-313, Portugal.
  • Segundo MA; LAQV, REQUIMTE, Departamento de Ciências Químicas, Faculdade de Farmácia, Universidade do Porto, Rua Jorge Viterbo Ferreira no 228, Porto 4050-313, Portugal.
J Anal Methods Chem ; 2020: 8821809, 2020.
Article em En | MEDLINE | ID: mdl-32953194
ABSTRACT
Zinc is an essential trace element for animals in several biological processes, particularly in energy production, and it is acquired from food ingestion. In this context, a microplate-based fluorimetric assay was developed for simple, fast, and low-cost determination of zinc in pet food using 2,2'-((4-(2,7-difluoro-3,6-dihydroxy-4aH-xanthen-9-yl)-3-methoxyphenyl)azanediyl)diacetic acid (FluoZin-1) as fluorescent probe. Several aspects were studied, namely, the stability of the fluorescent product over time, the FluoZin-1 concentration, and the pH of reaction media. The developed methodology provided a limit of detection of 1 µg L-1 in sample acid digests, with a working range of 10 to 200 µg L-1, corresponding to 100-2000 mg of Zn per kg of dry dog food samples. Intraday repeatability and interday repeatability were assessed, with relative standard deviation values < 3.4% (100 µg L-1) and <11.7% (10 µg L-1). Sample analysis indicated that the proposed fluorimetric assay provided results consistent with ICP-MS analysis. These results demonstrated that the developed assay can be used for rapid determination of zinc in dry dog food.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Anal Methods Chem Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Anal Methods Chem Ano de publicação: 2020 Tipo de documento: Article