Development of a DNA-based biosensor for the fast and sensitive detection of ochratoxin A in urine.
Santovito, Elisa; Greco, Donato; D'Ascanio, Vito; Sanzani, Simona Marianna; Avantaggiato, Giuseppina.
Afiliação
  • Santovito E; Istituto di Scienze Delle Produzioni Alimentari (ISPA), Consiglio Nazionale Delle Ricerche (CNR), Via Amendola 122/O, 70126, Bari, Italy. Electronic address: elisa.santovito@ispa.cnr.it.
  • Greco D; Istituto di Scienze Delle Produzioni Alimentari (ISPA), Consiglio Nazionale Delle Ricerche (CNR), Via Amendola 122/O, 70126, Bari, Italy.
  • D'Ascanio V; Istituto di Scienze Delle Produzioni Alimentari (ISPA), Consiglio Nazionale Delle Ricerche (CNR), Via Amendola 122/O, 70126, Bari, Italy.
  • Sanzani SM; CIHEAM Bari, Via Ceglie 9, 70010, Valenzano, BA, Italy.
  • Avantaggiato G; Istituto di Scienze Delle Produzioni Alimentari (ISPA), Consiglio Nazionale Delle Ricerche (CNR), Via Amendola 122/O, 70126, Bari, Italy.
Anal Chim Acta ; 1133: 20-29, 2020 Oct 09.
Article em En | MEDLINE | ID: mdl-32993870
In this paper, a novel DNA-based biosensor is proposed, which is based on paramagnetic microbeads carrying an ochratoxin A (OTA) capture aptamer. A sandwich-like detection complex is linked to the capture aptamer and is able to trigger, in presence of OTA, an isothermal rolling circle amplification (RCA) reaction. This latter generated autocatalytic units with a peroxidase activity (DNAzyme) that, in presence of a proper substrate, gave a blue-coloured product visible by the naked eye. The capture aptamer, blocked onto magnetic beads, allowed the specific capture of OTA in liquid samples. The modified detection aptamer, annealed to a circularized probe, was then used to detect the toxin capture event. Indeed, in the presence of OTA and an isothermal enzyme, the circular DNA was amplified, producing a single-stranded and tandem repeated long homologous copy of its sequence. In the DNA strand, a self-catalytic structure was formed with hemin as the catalytic core, inducing the development of blue colour in the presence of ABTS and hydrogen peroxide. The results showed that the biosensor has high sensitivity and selectivity for the detection of OTA, as low as 1.09 × 10-12 ng/mL. Moreover, the proposed biosensor was successfully used for the detection of OTA in naturally contaminated rat urine. Accuracy and repeatability data obtained in recovery experiments were satisfying, being recoveries >95% with relative standard deviations in the range 3.6-15%. For the first time, an aptasensor was successfully applied to detect OTA in biological fluids. It can be used for mycotoxin biomonitoring and assessment of individual exposure.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Ocratoxinas Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Anal Chim Acta Ano de publicação: 2020 Tipo de documento: Article