Multi-label classification (MLC) is deemed as an effective and dynamic research topic in the medical image analysis field. For ophthalmologists, MLC benefits can be utilized to detect early diabetic retinopathy (DR) signs, as well as its different grades. This paper proposes a comprehensive computer-aided diagnostic (CAD) system that exploits the MLC of DR grades using colored fundus photography. The proposed system detects and analyzes various retina pathological changes accompanying DR development. We extracted some significant features to differentiate healthy from DR cases as well as differentiate various DR grades. First, we preprocessed the retinal images to eliminate noise and enhance the image quality by using histogram equalization for brightness preservation based on dynamic stretching technique. Second, the images were segmented to extract four pathology variations, which are blood vessels, exudates, microaneurysms, and hemorrhages. Next, six various features were extracted using a gray level co-occurrence matrix, the four extracting areas, and blood-vessel bifurcation points. Finally, the features were supplied to a support vector machine (SVM) classifier to distinguish normal and different DR grades. To train and test the proposed system, we utilized four benchmark datasets (two of them are multi-label datasets) using six performance metrics. The proposed system achieved an average accuracy of 89.2%, sensitivity of 85.1%, specificity of 85.2%, positive predictive value of 92.8%, area under the curve of 85.2%, and Disc similarity coefficient (DSC) of 88.7%. The experiments show promising results as compared with other systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus / Retinopatia Diabética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Comput Biol Med Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus / Retinopatia Diabética Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Comput Biol Med Ano de publicação: 2020 Tipo de documento: Article