Your browser doesn't support javascript.
loading
Refinement of the Peroxidase Peptide Reactivity Assay and Prediction Model for Assessing Skin Sensitization Potential.
Ryan, Cindy A; Troutman, John A; Kern, Petra S; Quijano, Mike; Dobson, Roy L M; Jian Dai, Hong; Burt, Thomas M; Gerberick, G Frank.
Afiliação
  • Ryan CA; Global Product Stewardship, Mason Business Center, The Procter & Gamble Company, Mason, Ohio 45040.
  • Troutman JA; Global Product Stewardship, Mason Business Center, The Procter & Gamble Company, Mason, Ohio 45040.
  • Kern PS; Central Product Safety, Brussels Innovation Center, Procter & Gamble Eurocor, B-1853 Strombeek-Bever, Belgium.
  • Quijano M; Corporate Functions Analytical, Mason Business Center, The Procter & Gamble Company, Cincinnati, Ohio 45040.
  • Dobson RLM; Corporate Functions Analytical, Mason Business Center, The Procter & Gamble Company, Cincinnati, Ohio 45040.
  • Jian Dai H; Corporate Functions Analytical, Mason Business Center, The Procter & Gamble Company, Cincinnati, Ohio 45040.
  • Burt TM; Corporate Functions Analytical, Mason Business Center, The Procter & Gamble Company, Cincinnati, Ohio 45040.
  • Gerberick GF; GF3 Consultancy LLC, West Chester, Ohio 45069.
Toxicol Sci ; 178(1): 88-103, 2020 11 01.
Article em En | MEDLINE | ID: mdl-33094344
ABSTRACT
A peptide reactivity assay with an activation component was developed for use in screening chemicals for skin sensitization potential. A horseradish peroxidase-hydrogen peroxide (HRP/P) oxidation system was incorporated into the assay for characterizing reactivity of hapten and pre-/prohapten sensitizers. The assay, named the Peroxidase Peptide Reactivity Assay (PPRA) had a predictive accuracy of 83% (relative to the local lymph node assay) with the original protocol and prediction model. However, apparent false positives attributed to cysteine depletion at relatively high chemical concentrations and, for some chemicals expected to react with the -NH2 group of lysine, little to no depletion of the lysine peptide were observed. To improve the PPRA, cysteine peptide reactions with and without HRP/P were modified by increasing the number of test concentrations and refining their range. In addition, removal of DL-dithiothreitol from the reaction without HRP/P increased cysteine depletion and improved detection of reactive aldehydes and thiazolines without compromising the assay's ability to detect prohaptens. Modification of the lysine reaction mixture by changing the buffer from 0.1 M ammonium acetate buffer (pH 10.2) to 0.1 M phosphate buffer (pH 7.4) and increasing the level of organic solvent from 1% to 25% resulted in increased lysine depletion for known lysine reactive chemicals. Refinement of the prediction model improved the sensitivity, specificity, and accuracy for hazard identification. These changes resulted in significant improvement of the PPRA making it is a reliable method for predicting the skin sensitization potential of all chemicals, including pre-/prohaptens and directly reactive haptens.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peroxidases / Dermatite Alérgica de Contato / Alternativas aos Testes com Animais Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: Toxicol Sci Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peroxidases / Dermatite Alérgica de Contato / Alternativas aos Testes com Animais Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: Toxicol Sci Ano de publicação: 2020 Tipo de documento: Article