Your browser doesn't support javascript.
loading
Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma.
Iwamuro, Masaya; Takahashi, Takahide; Watanabe, Natsuki; Omote, Sizuma; Matsueda, Katsunori; Tanaka, Takehiro; Ennishi, Daisuke; Otsuka, Fumio; Yoshino, Tadashi; Okada, Hiroyuki.
Afiliação
  • Iwamuro M; Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
  • Takahashi T; Division of Medical Support, Okayama University Hospital, Okayama 700-8558, Japan.
  • Watanabe N; Division of Medical Support, Okayama University Hospital, Okayama 700-8558, Japan.
  • Omote S; Department of Pathology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
  • Matsueda K; Department of Gastrointestinal Oncology, Osaka International Cancer Institute, Osaka 541-8567, Japan.
  • Tanaka T; Department of Pathology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
  • Ennishi D; Department of Hematology and Oncology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
  • Otsuka F; Department of General Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
  • Yoshino T; Department of Pathology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
  • Okada H; Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama 700-8558, Japan.
MethodsX ; 7: 101095, 2020.
Article em En | MEDLINE | ID: mdl-33102158
ABSTRACT
In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the lymphocyte suspension, the solid specimen was crushed using the rubber portion of a plunger of a 10 mL injection syringe. Flow cytometry was performed using the lymphocyte suspension. For validating our methods, the one-step lymphocyte isolation technique was used to perform flow cytometry on samples from 23 patients with (n = 12) or without (n = 11) gastrointestinal lymphoma. Flow cytometry of light chain expression was performed in all patient samples (feasibility 100%). Sensitivity was 83.3% (10/12) and specificity was 100% (11/11). In conclusion, lymphocytes isolated from a single endoscopic biopsy specimen using our simplified and quick procedure are suitable for flow cytometry. Considering that flow cytometry has an important advantage of providing the results on the examination day itself, the results of this study suggest that flow cytometric analysis using our single-step lymphocyte isolation technique can be potentially used to diagnose lymphoma in the gastrointestinal mucosa. •We introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment.•Our technique is feasible for flow cytometric analysis in patients with gastrointestinal lymphoma as well as those with gastrointestinal lesions that are suspected to be lymphoma.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: MethodsX Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: MethodsX Ano de publicação: 2020 Tipo de documento: Article