Your browser doesn't support javascript.
loading
Rapid mono and biexponential 3D-T mapping of knee cartilage using variational networks.
Zibetti, Marcelo V W; Johnson, Patricia M; Sharafi, Azadeh; Hammernik, Kerstin; Knoll, Florian; Regatte, Ravinder R.
Afiliação
  • Zibetti MVW; Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, 660 1st Ave, 4th Floor, New York, NY, 10016, USA. Marcelo.WustZibetti@nyulangone.org.
  • Johnson PM; Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, 660 1st Ave, 4th Floor, New York, NY, 10016, USA.
  • Sharafi A; Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, 660 1st Ave, 4th Floor, New York, NY, 10016, USA.
  • Hammernik K; Department of Computing, Imperial College London, London, UK.
  • Knoll F; Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, 660 1st Ave, 4th Floor, New York, NY, 10016, USA.
  • Regatte RR; Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, 660 1st Ave, 4th Floor, New York, NY, 10016, USA.
Sci Rep ; 10(1): 19144, 2020 11 05.
Article em En | MEDLINE | ID: mdl-33154515
ABSTRACT
In this study we use undersampled MRI acquisition methods to obtain accelerated 3D mono and biexponential spin-lattice relaxation time in the rotating frame (T1ρ) mapping of knee cartilage, reducing the usual long scan time. We compare the accelerated T1ρ maps obtained by deep learning-based variational network (VN) and compressed sensing (CS). Both methods were compared with spatial (S) and spatio-temporal (ST) filters. Complex-valued fitting was used for T1ρ parameters estimation. We tested with seven in vivo and six synthetic datasets, with acceleration factors (AF) from 2 to 10. Median normalized absolute deviation (MNAD), analysis of variance (ANOVA), and coefficient of variation (CV) were used for analysis. The methods CS-ST, VN-S, and VN-ST performed well for accelerating monoexponential T1ρ mapping, with MNAD around 5% for AF = 2, which increases almost linearly with the AF to an MNAD of 13% for AF = 8, with all methods. For biexponential mapping, the VN-ST was the best method starting with MNAD of 7.4% for AF = 2 and reaching MNAD of 13.1% for AF = 8. The VN was able to produce 3D-T1ρ mapping of knee cartilage with lower error than CS. The best results were obtained by VN-ST, improving CS-ST method by nearly 7.5%.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Cartilagem Articular / Articulação do Joelho Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Cartilagem Articular / Articulação do Joelho Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Sci Rep Ano de publicação: 2020 Tipo de documento: Article