Your browser doesn't support javascript.
loading
Electrospun nitrocellulose membrane for immunochromatographic test strip with high sensitivity.
Wang, Xue; Yang, Dong; Jia, Shun-Tian; Zhao, Ling-Ling; Jia, Tong-Tong; Xue, Chao-Hua.
Afiliação
  • Wang X; College of Environmental Science and Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China.
  • Yang D; College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China. yangdong@sust.edu.cn.
  • Jia ST; College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China.
  • Zhao LL; College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China.
  • Jia TT; College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China.
  • Xue CH; College of Environmental Science and Engineering, Shaanxi University of Science and Technology, Xi'an, 710021, China. xuechaohua@126.com.
Mikrochim Acta ; 187(12): 644, 2020 11 06.
Article em En | MEDLINE | ID: mdl-33155110
ABSTRACT
The main goal of this work is to develop an economical, portable, disposable, and reliable point of care paper biosensor based on visualization, which can be used to detect viruses, bacteria, and proteins. However, the sensitivity of immunochromatography test (ICT) strips based on nitrocellulose to target detection has always been a problem. Here, we use an electrospun nitrocellulose (ENC) fiber membrane instead of traditional nitrocellulose fiber membrane to construct ICT strips for early pregnancy detection. By proper selection of the diameter of the ENC fiber to adjust the pore size, porosity, and morphology of the membrane, ICT strips with low flow rate and high protein loading were obtained. Based on these properties, a convenient and sensitive method for the colorimetric determination of human chorionic gonadotropin was developed. Under the optimal conditions, the detection limit of ICT based on ENC membrane is 10 mIU mL-1 (S/N = 3), the linear detection range is 5-1000 mIU mL-1, and the linear relationship is Y = 0.0434 X - 0.0136 (R2 = 0.9802). In addition, the test strip has good specificity and stability, and will not produce false-positive results. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia de Afinidade / Colódio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia de Afinidade / Colódio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2020 Tipo de documento: Article