Your browser doesn't support javascript.
loading
Biomechanical evaluation of four different posterior instrumentation techniques for single-level transforaminal lumbar interbody fusion: a finite element analysis.
Guo, Hui-Zhi; Tang, Yong-Chao; Guo, Dan-Qing; Liang, De; Zhang, Shun-Cong.
Afiliação
  • Guo HZ; The First Institute of Clinical Medicine, Guangzhou University of Chinese Medicine Guangzhou, Guangdong, China.
  • Tang YC; Spine Surgery Department, The First Affiliated Hospital of Guangzhou University of Chinese Medicine Guangzhou, Guangdong, China.
  • Guo DQ; Spine Surgery Department, The First Affiliated Hospital of Guangzhou University of Chinese Medicine Guangzhou, Guangdong, China.
  • Liang; The First Institute of Clinical Medicine, Guangzhou University of Chinese Medicine Guangzhou, Guangdong, China.
  • Zhang SC; Spine Surgery Department, The First Affiliated Hospital of Guangzhou University of Chinese Medicine Guangzhou, Guangdong, China.
Am J Transl Res ; 12(10): 6160-6169, 2020.
Article em En | MEDLINE | ID: mdl-33194021
ABSTRACT
This study aims to investigate the fixation strength of unilateral cortical bone trajectory screw fixation (UCBT) and UCBT with contralateral translaminar facet screw fixation (UCBT-TFS) by repeating the verification of three finite element models. Three healthy female models of the lumbosacral spine were constructed. For each of them, four transforaminal lumbar interbody fusion (TLIF) models with the following instruments were created bilateral traditional trajectory pedicle screw fixation (TT), bilateral cortical bone trajectory screw fixation (CBT), UCBT, and UCBT-TFS. A 150-N compressive load with 10 N/m moments was applied to simulate flexion, extension, lateral bending, and axial rotation. The range of motion (ROM), the stress of the cages, and the stress of the posterior fixations were compared. TT and UCBT-TFS had a similar low ROM compared to the intact models, and CBT showed a higher ROM in lateral bending. UCBT resulted in the highest ROM under all loading conditions, especially in lateral bending (116% and 170% greater than TT in left bending and right bending). UCBT induced a significant increase in the peak stress of cages and instruments, followed by CBT and UCBT-TFS, and the lowest mean values were observed for TT. Among the four different fixation techniques, TT offered the highest fixation strength and lowest implant stress, followed by UCBT-TFS and CBT, while UCBT was the least stable and resulted in increased stress of the screws and cages. UCBT-TFS improved biomechanical stability and appeared to be a less invasive alternative in well-selected patients with single-level TLIF.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Am J Transl Res Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Am J Transl Res Ano de publicação: 2020 Tipo de documento: Article