Your browser doesn't support javascript.
loading
Metabolomics Approach for Discrimination and Quality Control of Natural and Commercial Fallopia multiflora Products in Vietnam.
Thoa, Nguyen Thi; Dang, Nguyen Hai; Giang, Do Hoang; Thu Minh, Nguyen Thi; Dat, Nguyen Tien.
Afiliação
  • Thoa NT; Graduate University of Science and Technology, Vietnam Academy of Science and Technology, 18-Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam.
  • Dang NH; Faculty of Chemical Technology, Hanoi University of Industry, 298-Cau Dien, Bac Tu Liem, Hanoi, Vietnam.
  • Giang DH; University of Science and Technology of Hanoi, Vietnam Academy of Science and Technology, 18-Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam.
  • Thu Minh NT; Center for Research and Technology Transfer, Vietnam Academy of Science and Technology, 18-Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam.
  • Dat NT; Center for Research and Technology Transfer, Vietnam Academy of Science and Technology, 18-Hoang Quoc Viet, Cau Giay, Hanoi, Vietnam.
Int J Anal Chem ; 2020: 8873614, 2020.
Article em En | MEDLINE | ID: mdl-33204273
ABSTRACT
A precise HPLC-DAD-based quantification together with the metabolomics statistical method was developed to distinguish and control the quality of Fallopia multiflora, a popular medicinal material in Vietnam. Multivariate statistical methods such as hierarchical clustering analysis and principal component analysis were utilized to compare and discriminate six natural and twelve commercial samples. 2,3,4',5-Tetrahydroxystilbene 2-O-ß-D-glucopyranoside (THSG) (1), emodin (4), and the new compound 6-hydroxymusizin 8-O-α-D-apiofuranosyl-(1⟶6)-ß-D-glucopyranoside (5) could be considered as important markers for classification of F. multiflora. Furthermore, seven phenolics were quantified that the variation in the contents of selected metabolites revealed the differences in the quality of natural and commercial samples. Recovery of the compounds from the analytes was more than 98%, while the limits of detection (LOD) and the limits of quantitation (LOQ) ranged from 0.5 to 6.6 µg/ml and 1.5 to 19.8 µg/ml, respectively. The linearity, LOD, LOQ, precision, and accuracy satisfied the criteria FDA guidance on bioanalytical methods. Overall, this method is a promising tool for discrimination and quality assurance of F. multiflora products.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Int J Anal Chem Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Int J Anal Chem Ano de publicação: 2020 Tipo de documento: Article