Modeling of Virtual Mechanical Circulatory Hemodynamics for Biventricular Heart Failure Support.
Cardiovasc Eng Technol
; 11(6): 699-707, 2020 12.
Article
em En
| MEDLINE
| ID: mdl-33215365
OBJECTIVE: In this study, a mechanical circulatory support simulation tool was used to investigate the application of a unique device with two centrifugal pumps and one motor for the biventricular assist device (BVAD) support application. Several conditions-including a range of combined left and right systolic heart failure severities, aortic and pulmonary valve regurgitation, and combinations of high and low systemic and pulmonary vascular resistances-were considered in the simulation matrix. Relative advantages and limitations of using the device in BVAD applications are discussed. METHODS: The simulated BVAD pump was based on the Cleveland Clinic pediatric continuous-flow total artificial heart (P-CFTAH), which is currently under development. Different combined disease states (n = 10) were evaluated to model the interaction with the BVAD, considering combinations of normal heart, moderate failure and severe systolic failure of the left and right ventricles, regurgitation of the aortic and pulmonary valves and combinations of vascular resistance. The virtual mock loop simulation tool (MATLAB; MathWorks®, Natick, MA) simulates the hemodynamics at the pump ports using a lumped-parameter model for systemic/pulmonary circulation characteristic inputs (values for impedance, systolic and diastolic ventricular compliance, beat rate, and blood volume), and characteristics of the cardiac chambers and valves. RESULTS: Simulation results showed that this single-pump BVAD can provide regulated support of up to 5 L/min over a range of combined heart failure states and is suitable for smaller adult and pediatric support. However, good self-regulation of the atrial pressure difference was not maintained with the introduction of aortic valve regurgitation or high systemic vascular resistance when combined with low pulmonary vascular resistance. CONCLUSIONS: This initial in silico study demonstrated that use of the P-CFTAH as a BVAD supports cardiac output and arterial pressure in biventricular heart failure conditions. A similar but larger device would be required for a large adult patient who needs more than 5 L/min of support.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Coração Auxiliar
/
Função Ventricular Esquerda
/
Função Ventricular Direita
/
Implantação de Prótese
/
Insuficiência Cardíaca
/
Hemodinâmica
/
Modelos Cardiovasculares
Tipo de estudo:
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
Cardiovasc Eng Technol
Ano de publicação:
2020
Tipo de documento:
Article