Rectal Perforation by an Intrauterine Device Leading to Fatal Intra-Abdominal Sepsis and Necrotizing Fasciitis.
J Obstet Gynaecol Can
; 43(6): 760-762, 2021 Jun.
Article
em En
| MEDLINE
| ID: mdl-33268310
ABSTRACT
BACKGROUND:
Colorectal injury from an intrauterine device (IUD) is rare but may lead to major complications. CASE A 55-year-old woman presented to a tertiary care hospital with 4 days of generalized weakness, confusion, dysuria, and lower back pain. She provided a vague history of an unsuccessful attempt to remove an IUD 30 years prior. A computed tomography scan demonstrated an IUD in the rectal lumen, with gluteal and pelvic gas and fluid collections. Emergency surgery found necrotizing fasciitis. Despite multiple debridements, sigmoidoscopic IUD removal, and long-term intravenous antibiotics, the patient died from sepsis and multiorgan failure.CONCLUSION: