Your browser doesn't support javascript.
loading
Clinical usefulness of single photon emission tomography/computed tomography with stress analysis in early diagnoses of stem instability of noncemented hip arthroplasty.
Zhang, Li-Zhi; Li, Shuang; Jiang, Yao; Qiu, Zhong-Ling; Wang, Yang; Lu, Han-Kui; Zhu, Rui-Sen; Tuladhar, Rujan; Chang, Shi-Min.
Afiliação
  • Zhang LZ; Department of Orthopedic Surgery, ShangHai YangPu District Central Hospital, YangPu Hospital, TongJi University.
  • Li S; Department of Orthopaedic Surgery, Pudong New Area Poeples' Hospital, Shanghai University of Medicine and Health Sciences.
  • Jiang Y; Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Qiu ZL; Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Wang Y; Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Lu HK; Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Zhu RS; Department of Orthopedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University, Shanghai, China.
  • Tuladhar R; Department of Orthopedic Surgery, ShangHai YangPu District Central Hospital, YangPu Hospital, TongJi University.
  • Chang SM; Department of Orthopedic Surgery, ShangHai YangPu District Central Hospital, YangPu Hospital, TongJi University.
Nucl Med Commun ; 42(3): 244-252, 2021 Mar 01.
Article em En | MEDLINE | ID: mdl-33306622
ABSTRACT

OBJECTIVE:

Hip pain arising from implant instability is generally caused by repetitive stress injury, which subsequently leads to induction or exacerbation of abnormal metabolism of bone around the implant. single photon emission tomography/computed tomography (SPECT-CT) has advantages in localizing areas of increased tracer uptake that reflects such abnormal bone metabolism. Therefore, we investigated whether the application of SPECT/CT with stress analysis can be an effective practice in evaluating the instability of stem in noncemented hip arthroplasty or not.

METHOD:

In total 16 patients were collected for unexplained painful hip arthroplasties. When physical examination and blood tests were unremarkable, radiographs were inconclusive and bone scan indicated increased scintigraphic uptake at the proximal part and at the tip of the stem; SPECT/CT was performed. Stem stability was assessed by measuring whether there was consistency between the increased scintigraphic uptake and the direction of the stress around the implant along with the location of the prosthesis.

RESULT:

Among the 16 symptomatic hips, 9 hips showed the stability of the stem, 3 hips showed the stem instability and 4 hips showed the acetabular loosening with the stem stability. With the application of SPECT/CT with stress analysis, 15 out of 16 (93.7%) cases were found to have the change in the diagnoses, and managements were implemented in 11 out of 16 (68.7%) cases. When comparing before and after SPECT/CT, there was no significant association in clinical diagnosis and management (Pearson chi- square test = 4.61 and 1.33, P = 0.33 and 0.25).

CONCLUSION:

SPECT/CT combined with stress analysis can be a useful tool in early diagnosis of stem instability and can assist surgeons in subsequent management and decision implementation when other radiographic imagings are inconclusive.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estresse Mecânico / Falha de Prótese / Artroplastia de Quadril / Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Nucl Med Commun Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estresse Mecânico / Falha de Prótese / Artroplastia de Quadril / Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único Tipo de estudo: Diagnostic_studies / Prognostic_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Nucl Med Commun Ano de publicação: 2021 Tipo de documento: Article