Novel dual multiplex real-time RT-PCR assays for the rapid detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus using the BD MAX open system.
Chung, Hsing-Yi; Jian, Ming-Jr; Chang, Chih-Kai; Lin, Jung-Chung; Yeh, Kuo-Ming; Chen, Chien-Wen; Chiu, Sheng-Kang; Wang, Yi-Hui; Liao, Shu-Jung; Li, Shih-Yi; Hsieh, Shan-Shan; Tsai, Shih-Hung; Perng, Cherng-Lih; Yang, Ji-Rong; Liu, Ming-Tsan; Chang, Feng-Yee; Shang, Hung-Sheng.
Afiliação
  • Chung HY; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Jian MJ; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Chang CK; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Lin JC; Division of Infectious Diseases and Tropical Medicine, Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Yeh KM; Division of Infectious Diseases and Tropical Medicine, Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Chen CW; Division of Pulmonary and Critical Care Medicine, Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Chiu SK; Division of Infectious Diseases and Tropical Medicine, Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Wang YH; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Liao SJ; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Li SY; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Hsieh SS; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Tsai SH; Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Perng CL; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Yang JR; Centers for Disease Control, Taipei, Taiwan, ROC.
  • Liu MT; Centers for Disease Control, Taipei, Taiwan, ROC.
  • Chang FY; Division of Infectious Diseases and Tropical Medicine, Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
  • Shang HS; Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC.
Emerg Microbes Infect ; 10(1): 161-166, 2021 Dec.
Article em En | MEDLINE | ID: mdl-33410371
ABSTRACT
SARS-CoV-2 has spread rapidly, causing deaths worldwide. In this study, we evaluated the performance of the BD MAX Open System module for identifying viral pathogens, including SARS-CoV-2, in nasopharyngeal specimens from individuals with symptoms of upper respiratory tract infection. We developed and validated a rapid total nucleic acid extraction method based on real-time reverse transcription-polymerase chain reaction (RT-PCR) for the reliable, high-throughput simultaneous detection of common cold viral pathogens using the BD MAX Platform. The system was evaluated using 205 nasopharyngeal swab clinical samples. For assessment of the limit of detection (LoD), we used SARS-CoV-2, influenza A/B, and respiratory syncytial virus (RSV) RNA standards. The BD MAX dual multiplex real-time RT-PCR panel demonstrated a sensitivity comparable to that of the World Health Organization-recommended SARS-CoV-2 assay with an LoD of 50 copies/PCR. The LoD of influenza A/B and RSV was 100-200 copies/PCR. The overall percent agreement between the BD MAX panel and laboratory-developed RT-PCR test on 55 SARS-CoV-2-positive clinical samples was 100%. Among the 55 positive cases of COVID-19 analysed, no coinfection was detected. The BD MAX rapid multiplex PCR provides a highly sensitive, robust, and accurate assay for the rapid detection of SARS-CoV-2, influenza A/B, and RSV.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Reação em Cadeia da Polimerase / Infecções por Vírus Respiratório Sincicial / Influenza Humana / SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Emerg Microbes Infect Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Reação em Cadeia da Polimerase / Infecções por Vírus Respiratório Sincicial / Influenza Humana / SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Emerg Microbes Infect Ano de publicação: 2021 Tipo de documento: Article