Your browser doesn't support javascript.
loading
Comparison of artificial tooth position in dentures fabricated by heat curing and additive manufacturing.
Tasaka, A; Okano, H; Odaka, K; Matsunaga, S; K Goto, T; Abe, S; Yamashita, S.
Afiliação
  • Tasaka A; Department of Removable Partial Prosthodontics, Tokyo Dental College, Tokyo, Japan.
  • Okano H; Oral Health Science Center, Tokyo Dental College, Tokyo, Japan.
  • Odaka K; Department of Removable Partial Prosthodontics, Tokyo Dental College, Tokyo, Japan.
  • Matsunaga S; Oral Health Science Center, Tokyo Dental College, Tokyo, Japan.
  • K Goto T; Department of Oral and Maxillofacial Radiology, Tokyo Dental College, Tokyo, Japan.
  • Abe S; Oral Health Science Center, Tokyo Dental College, Tokyo, Japan.
  • Yamashita S; Department of Anatomy, Tokyo Dental College, Tokyo, Japan.
Aust Dent J ; 66(2): 182-187, 2021 06.
Article em En | MEDLINE | ID: mdl-33411950
ABSTRACT

BACKGROUND:

The purpose of this study was to compare the displacement of tooth arrangement in dentures fabricated by additive manufacturing (AM) and heat curing.

METHODS:

Three-dimensional (3D) scanning was performed for edentulous jaw models. After the teeth were arranged, 3D scanning for the wax denture was performed. Heat-cured dentures were fabricated with heat-cure polymer resin. Based on data obtained by subtracting the model data from wax denture data, AM dentures were fabricated from ultraviolet-cured acrylic resin. Accuracy was verified by superimposing heat-cured and AM dentures on the tooth region data from the wax dentures and measuring displacement of the tooth arrangement.

RESULTS:

In the maxillary dentures, the amount of tooth displacement for the heat-cured dentures and for the AM dentures ranged from -0.08 to +0.06 mm and from -0.25 to +0.06 mm respectively. A significant difference was observed between two dentures. In the mandibular dentures, the amount of tooth displacement for the heat-cured dentures and for the AM dentures ranged from -0.09 to +0.07 mm and from -0.03 to +0.07 mm respectively. No significant difference was observed between two dentures.

CONCLUSIONS:

The artificial teeth of the maxillary dentures fabricated by AM showed a greater displacement compared to those by heat curing.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dente Artificial / Temperatura Alta Limite: Humans Idioma: En Revista: Aust Dent J Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dente Artificial / Temperatura Alta Limite: Humans Idioma: En Revista: Aust Dent J Ano de publicação: 2021 Tipo de documento: Article