Your browser doesn't support javascript.
loading
A simple, one-pot and ultrasensitive DNA sensor via Exo III-Assisted target recycling and 3D DNA walker cascade amplification.
Wu, Na; Wang, Yi-Ting; Wang, Xiao-Yan; Chen, Xu-Wei; Yang, Ting; Wang, Jian-Hua.
Afiliação
  • Wu N; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Wang YT; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Wang XY; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Chen XW; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Yang T; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China. Electronic address: yangting@mail.neu.edu.cn.
  • Wang JH; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
Anal Chim Acta ; 1147: 15-22, 2021 Feb 22.
Article em En | MEDLINE | ID: mdl-33485573
ABSTRACT
Rapid, sensitive, and user-friendly nucleic acid detection is of growing importance in early clinical diagnosis. Here, we construct a simple, one-pot and ultrasensitive DNA sensor via exonuclease III (Exo III)-assisted target recycling amplification (ERA) combined with 3D DNA walker cascade amplification. In the presence of single-stranded DNA target, the ERA process is activated to generate numerous walker strands (WS). Thereafter, Exo III-powered WSs autonomously move along magnetic bead (MB)-based 3D track to release numerous AgNCs into the supernatant as an amplified signal output. This biosensor had a low detection limit of 18 fM and an analytical range of 40 fM to 1 pM. Furthermore, the practical application potential of this biosensor was also confirmed by the spiking experiments of p53 into human serum and urine samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Exodesoxirribonucleases Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Exodesoxirribonucleases Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2021 Tipo de documento: Article