Your browser doesn't support javascript.
loading
Comparison of posterior capsule opacification between Clareon CNA0T0 and Tecnis ZCB00 intraocular lenses.
Almenara, Cristina; Bartol-Puyal, Francisco de Asís; Soriano, Diana; Idoipe, Miriam; Chacón, María; Méndez-Martínez, Silvia; Giménez, Galadriel; Polo, Vicente.
Afiliação
  • Almenara C; Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.
  • Bartol-Puyal FA; Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.
  • Soriano D; Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain.
  • Idoipe M; Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.
  • Chacón M; Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.
  • Méndez-Martínez S; Department of Surgery, Obstetrics and Gynecology, University of Zaragoza, Spain.
  • Giménez G; Ophthalmology Department, Nuestra Señora de Gracia Hospital, Zaragoza, Spain.
  • Polo V; Aragon Health Research Institute (IIS Aragón), Miguel Servet Ophthalmology Research Group (GIMSO), Zaragoza, Spain.
Eur J Ophthalmol ; 31(6): 3355-3366, 2021 Nov.
Article em En | MEDLINE | ID: mdl-33522302
ABSTRACT

INTRODUCTION:

The purpose is to compare posterior capsule opacification (PCO) and its impact on vision between Clareon CNA0T0 (Alcon) and Tecnis ZCB00 intraocular lenses (IOLs) (Johnson&Johnson) 1, 6, and 12 months after implantation.

METHODS:

A prospective observational study was performed at the Nuestra Señora de Gracia Hospital (Zaragoza, Spain). Fifty eyes (50 patients) with Tecnis IOL (group 1) and 60 eyes (60 patients) with Clareon IOL (group 2) were enrolled. One, 6, and 12 months after age-related cataract surgery by five different surgeons, the following tests were performed mesopic corrected distance visual acuity (CDVA), CSV1000-E test, KR-1W wavefront analyzer, OQAS II, Catquest-9SF questionnaire and mydriatic slit-lamp pictures. PCO intensity was quantified and the area of opacification was measured using ImageJ (NIH).

RESULTS:

Mean age was 71.20 ± 6.79 years in group 1, and 71.73 ± 8.17 years in group 2 (p = 0.72); mean axial length was 23.46 ± 1.14 and 23.53 ± 0.91 mm, respectively (p = 0.72); mean IOL power was 21.69 ± 2.26 D and 21.28 ± 2.44 D, respectively (p = 0.37). One month after surgery there were differences in intensity of PCO (0.73 ± 0.60 and 1.05 ± 0.71, respectively, p = 0.02). Six months after surgery statistical differences were found in VA with 20% CS in mydriatic conditions (0.26 ± 0.21 logMAR (20/36) and 0.18 ± 0.17 logMAR (20/30), respectively, p = 0.04). Twelve months after surgery, no differences were detected between groups. As for the evolution of PCO within the Clareon group, high order aberrations (p < 0.05) and the Strehl ratio (p = 0.02) decreased.

CONCLUSION:

There are no differences in slit-lamp pictures or visual function between both IOLs during the first 12 months after implantation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Facoemulsificação / Opacificação da Cápsula / Lentes Intraoculares Tipo de estudo: Etiology_studies / Observational_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Eur J Ophthalmol Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Facoemulsificação / Opacificação da Cápsula / Lentes Intraoculares Tipo de estudo: Etiology_studies / Observational_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Eur J Ophthalmol Ano de publicação: 2021 Tipo de documento: Article