Your browser doesn't support javascript.
loading
Unsupervised Flow Cytometry Analysis Allows for an Accurate Identification of Minimal Residual Disease Assessment in Acute Myeloid Leukemia.
Vial, Jean Philippe; Lechevalier, Nicolas; Lacombe, Francis; Dumas, Pierre-Yves; Bidet, Audrey; Leguay, Thibaut; Vergez, François; Pigneux, Arnaud; Béné, Marie C.
Afiliação
  • Vial JP; Hematology Biology, Flow Cytometry, Bordeaux University Hospital, 33600 Pessac, France.
  • Lechevalier N; Hematology Biology, Flow Cytometry, Bordeaux University Hospital, 33600 Pessac, France.
  • Lacombe F; Hematology Biology, Flow Cytometry, Bordeaux University Hospital, 33600 Pessac, France.
  • Dumas PY; Service d'Hématologie Clinique et de Thérapie Cellulaire, Bordeaux University Hospital, 33600 Pessac, France.
  • Bidet A; Hematology Biology, Molecular Hematology, Bordeaux University Hospital, 33600 Pessac, France.
  • Leguay T; Service d'Hématologie Clinique et de Thérapie Cellulaire, Bordeaux University Hospital, 33600 Pessac, France.
  • Vergez F; Hematology Biology, IUCT Oncopôle, Toulouse University Hospital, 31000 Toulouse, France.
  • Pigneux A; Service d'Hématologie Clinique et de Thérapie Cellulaire, Bordeaux University Hospital, 33600 Pessac, France.
  • Béné MC; Hematology Biology, Nantes University Hospital, 44000 Nantes, France.
Cancers (Basel) ; 13(4)2021 Feb 05.
Article em En | MEDLINE | ID: mdl-33562525
ABSTRACT
The assessment of minimal residual disease (MRD) is increasingly considered to monitor response to therapy in hematological malignancies. In acute myeloblastic leukemia (AML), molecular MRD (mMRD) is possible for about half the patients while multiparameter flow cytometry (MFC) is more broadly available. However, MFC analysis strategies are highly operator-dependent. Recently, new tools have been designed for unsupervised MFC analysis, segregating cell-clusters with the same immunophenotypic characteristics. Here, the Flow-Self-Organizing-Maps (FlowSOM) tool was applied to assess MFC-MRD in 96 bone marrow (BM) follow-up (FU) time-points from 40 AML patients with available mMRD. A reference FlowSOM display was built from 19 healthy/normal BM samples (NBM), then simultaneously compared to the patient's diagnosis and FU samples at each time-point. MRD clusters were characterized individually in terms of cell numbers and immunophenotype. This strategy disclosed subclones with varying immunophenotype within single diagnosis and FU samples including populations absent from NBM. Detectable MRD was as low as 0.09% in MFC and 0.051% for mMRD. The concordance between mMRD and MFC-MRD was 80.2%. MFC yielded 85% specificity and 69% sensitivity compared to mMRD. Unsupervised MFC is shown here to allow for an easy and robust assessment of MRD, applicable also to AML patients without molecular markers.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Cancers (Basel) Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Cancers (Basel) Ano de publicação: 2021 Tipo de documento: Article