Your browser doesn't support javascript.
loading
A refined model on flow and oxygen consumption in the human cornea depending on the oxygen tension at the interface cornea/post lens tear film during contact lens wear.
Moreno, Vicente Compañ; Aguilella-Arzo, Marcel; Del Castillo, Roxana M; Espinós, Francisco J; Del Castillo, Luis Felipe.
Afiliação
  • Moreno VC; Departmento de Termodinámica Aplicada. Escuela Técnica Superior de Ingenieros Industriales (ETSII), Universitat Politécnica de Valencia, Campus de Vera s / n, 46020 Valencia, Spain.
  • Aguilella-Arzo M; Department de Física, Universitat Jaume I- 12080, Castellon, Spain.
  • Del Castillo RM; Departamento de Física, Facultad de Ciencias, Universidad Nacional Autónoma de México, Mexico City 04510, Mexico.
  • Espinós FJ; Centro de Investigación en Acuicultura y Medio Ambiente (ACUMA), Universitat Politècnica de València, Campus de Vera s / n, 46020 Valencia, Spain.
  • Del Castillo LF; Department of Polymers, Materials Research Institute, National Autonomous University of Mexico, Ap Postal 70-360, Coyoacan, Mexico City, Mexico.
J Optom ; 15(2): 160-174, 2022.
Article em En | MEDLINE | ID: mdl-33589396
ABSTRACT
The study of oxygen consumption rate under" in vivo" human cornea during contact lens wear has been technically a challenge and several attempts have been made in the last 20 years to model the physiology of the human cornea during contact lens wear. Unfortunately, some of these models, based on a constant corneal oxygen consumption rate, produce areas on the cornea where the oxygen tension is negative, which has no physical sense. In order to avoid such inconsistency, different researchers have developed alternative models of oxygen consumption, which predict the likely oxygen metrics available at the interface cornea/post lens tear film by determination of oxygen flux, oxygen consumption, and oxygen tension through the different layers (endothelium, stroma, and epithelium). Although oxygen deficiency produces corneal edema, corneal swelling, hypoxia, acidosis, and other abnormalities, the estimation of the oxygen distribution below the impact of a contact lens wear is interesting to know which lens transmissibility was adequate to maintain the cornea and avoid epithelial and stromal anoxia. The estimation of minimum transmissibility for a lens for extended wear applications will be very useful for both clinicians and manufacturers. The aim of this work is to present a complete discussion based on Monod kinetics model that permits give an estimation of oxygen partial pressure distribution, the profile distribution of corneal flux and oxygen consumption rate, and finally the estimation of the relaxation mechanism of the cornea depending on the oxygen tension at the interface cornea/post lens tear film. Relaxation time in this context can quantify the capability of the corneal tissue to adapt to increasing concentrations of oxygen. It is proposed this parameter as a biological meaningful indicator of the interaction between contact lens polymers and living tissues such as the corneal cellular layer.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lentes de Contato Hidrofílicas Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Optom Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lentes de Contato Hidrofílicas Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Optom Ano de publicação: 2022 Tipo de documento: Article