Your browser doesn't support javascript.
loading
Microphysiological System for High-Throughput Computer Vision Measurement of Microtissue Contraction.
Gracioso Martins, Ana Maria; Wilkins, Michael D; Ligler, Frances S; Daniele, Michael A; Freytes, Donald O.
Afiliação
  • Gracioso Martins AM; Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill/North Carolina State University, Raleigh 27695, North Carolina, United States.
  • Wilkins MD; Comparative Medicine Institute, North Carolina State University, Raleigh 27695, North Carolina, United States.
  • Ligler FS; Comparative Medicine Institute, North Carolina State University, Raleigh 27695, North Carolina, United States.
  • Daniele MA; Department of Electrical and Computer Engineering, North Carolina State University, Raleigh 27695, North Carolina, United States.
  • Freytes DO; Joint Department of Biomedical Engineering, University of North Carolina-Chapel Hill/North Carolina State University, Raleigh 27695, North Carolina, United States.
ACS Sens ; 6(3): 985-994, 2021 03 26.
Article em En | MEDLINE | ID: mdl-33656335
The ability to measure microtissue contraction in vitro can provide important information when modeling cardiac, cardiovascular, respiratory, digestive, dermal, and skeletal tissues. However, measuring tissue contraction in vitro often requires the use of high number of cells per tissue construct along with time-consuming microscopy and image analysis. Here, we present an inexpensive, versatile, high-throughput platform to measure microtissue contraction in a 96-well plate configuration using one-step batch imaging. More specifically, optical fiber microprobes are embedded in microtissues, and contraction is measured as a function of the deflection of optical signals emitted from the end of the fibers. Signals can be measured from all the filled wells on the plate simultaneously using a digital camera. An algorithm uses pixel-based image analysis and computer vision techniques for the accurate multiwell quantification of positional changes in the optical microprobes caused by the contraction of the microtissues. Microtissue constructs containing 20,000-100,000 human ventricular cardiac fibroblasts (NHCF-V) in 6 mg/mL collagen type I showed contractile displacements ranging from 20-200 µm. This highly sensitive and versatile platform can be used for the high-throughput screening of microtissues in disease modeling, drug screening for therapeutics, physiology research, and safety pharmacology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaios de Triagem em Larga Escala / Fibroblastos Limite: Humans Idioma: En Revista: ACS Sens Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaios de Triagem em Larga Escala / Fibroblastos Limite: Humans Idioma: En Revista: ACS Sens Ano de publicação: 2021 Tipo de documento: Article