Your browser doesn't support javascript.
loading
Rapid identification of non-tuberculous mycobacteria with MALDI-TOF mass spectrometry.
Oliva, Ester; Arosio, Marco; Mazzola, Ester; Mascheroni, Miriam; Cerro, Annarosa; Cuntró, Marina; Vailati, Francesca; Cavallini, Marco; Farina, Claudio.
Afiliação
  • Oliva E; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Arosio M; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Mazzola E; Microbiology Unit, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
  • Mascheroni M; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Cerro A; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Cuntró M; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Vailati F; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Cavallini M; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
  • Farina C; Microbiology Unit, ASST Papa Giovanni XXIII, Bergamo, Italy.
Infez Med ; 29(1): 79-84, 2021 Mar 01.
Article em En | MEDLINE | ID: mdl-33664176
Rapid and accurate identification of non-tuberculous mycobacteria (NTM) is important for a prompt start to antibiotic therapy. The aim of this study was to obtain accurate identification of NTM quickly by analyzing the performance of the MALDI-TOF mass spectrometry (MS) system VITEK® MS in identifying various NTM species from solid medium and MGIT 960 liquid medium. The study was performed in two phases: preliminary and perspective. Overall, 41/42 species and 33/34 species were correctly identified from the MGIT medium in the preliminary and perspective phases, respectively. The VITEK® MS system includes in its database part of the mycobacteria from the Mycobacterium fortuitum complex but is unable to discriminate among the various species belonging to the complex. Although the VITEK® MS system does not have the protein spectrum of Mycobacterium chimaera, it is not able to distinguish between Mycobacterium chimaera and Mycobacterium intracellulare. Since the VITEK® MS includes the separate protein spectrum of both M. chelonae and M. abscessus, it can discriminate between the two microorganisms. Thanks to these studies we show that the VITEK® MS system is a reliable method for identification of NTMs directly from MGIT liquid medium, instead of the use of solid media.
Assuntos
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Micobactérias não Tuberculosas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Infez Med Ano de publicação: 2021 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Contexto em Saúde: 3_ND Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Micobactérias não Tuberculosas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Infez Med Ano de publicação: 2021 Tipo de documento: Article