Electrical Resistance Reduction Induced with CO2 Laser Single Line Scan of Polyimide.
Wang, Zhongke; Tan, Kok Keat; Lam, Yee Cheong.
Afiliação
  • Wang Z; SIMTech-NTU Joint Laboratory (Precision Machining), Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
  • Tan KK; Singapore Institute of Manufacturing Technology (SIMTech), A*STAR, 2 Fusionopolis Way, Singapore 138634, Singapore.
  • Lam YC; Singapore Institute of Manufacturing Technology (SIMTech), A*STAR, 2 Fusionopolis Way, Singapore 138634, Singapore.
Micromachines (Basel) ; 12(3)2021 Feb 24.
Article em En | MEDLINE | ID: mdl-33668402
ABSTRACT
We conducted a laser parameter study on CO2 laser induced electrical conductivity on a polyimide film. The induced electrical conductivity was found to occur dominantly at the center of the scanning line instead of uniformly across the whole line width. MicroRaman examination revealed that the conductivity was mainly a result of the multi-layers (4-5) of graphene structure induced at the laser irradiation line center. The graphene morphology at the line center appeared as thin wall porous structures together with nano level fiber structures. With sufficient energy dose per unit length and laser power, this surface modification for electrical conductivity was independent of laser pulse frequency but was instead determined by the average laser power. High electrical conductivity could be achieved by a single scan of laser beam at a sufficiently high-power level. To achieve high conductivity, it was not efficient nor effective to utilize a laser at low power but compensating it with a slower scanning speed or having multiple scans. The electrical resistance over a 10 mm scanned length decreased significantly from a few hundred Ohms to 30 Ohms when energy dose per unit length increased from 0.16 J/mm to 1.0 J/mm, i.e., the laser power increased from 5.0 W to 24 W with corresponding power density of 3.44 × 10 W/cm2 to 16.54 W/cm2 respectively at a speed of 12.5 mm/s for a single pass scan. In contrast, power below 5 W at speeds exceeding 22.5 mm/s resulted in a non-conductive open loop.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2021 Tipo de documento: Article