Your browser doesn't support javascript.
loading
Optical Method and Biochemical Source for the Assessment of the Middle-Molecule Uremic Toxin ß2-Microglobulin in Spent Dialysate.
Paats, Joosep; Adoberg, Annika; Arund, Jürgen; Fridolin, Ivo; Lauri, Kai; Leis, Liisi; Luman, Merike; Tanner, Risto.
Afiliação
  • Paats J; Department of Health Technologies, Tallinn University of Technology, 19086 Tallinn, Estonia.
  • Adoberg A; Centre of Nephrology, North Estonia Medical Centre, 13419 Tallinn, Estonia.
  • Arund J; Department of Health Technologies, Tallinn University of Technology, 19086 Tallinn, Estonia.
  • Fridolin I; Department of Health Technologies, Tallinn University of Technology, 19086 Tallinn, Estonia.
  • Lauri K; Department of Health Technologies, Tallinn University of Technology, 19086 Tallinn, Estonia.
  • Leis L; SYNLAB Eesti OÜ, 10138 Tallinn, Estonia.
  • Luman M; Centre of Nephrology, North Estonia Medical Centre, 13419 Tallinn, Estonia.
  • Tanner R; Department of Health Technologies, Tallinn University of Technology, 19086 Tallinn, Estonia.
Toxins (Basel) ; 13(4)2021 03 31.
Article em En | MEDLINE | ID: mdl-33807387
ABSTRACT
Optical monitoring of spent dialysate has been used to estimate the removal of water-soluble low molecular weight as well as protein-bound uremic toxins from the blood of end stage kidney disease (ESKD) patients. The aim of this work was to develop an optical method to estimate the removal of ß2-microglobulin (ß2M), a marker of middle molecule (MM) uremic toxins, during hemodialysis (HD) treatment. Ultraviolet (UV) and fluorescence spectra of dialysate samples were recorded from 88 dialysis sessions of 22 ESKD patients, receiving four different settings of dialysis treatments. Stepwise regression was used to obtain the best model for the assessment of ß2M concentration in the spent dialysate. The correlation coefficient 0.958 and an accuracy of 0.000 ± 0.304 mg/L was achieved between laboratory and optically estimated ß2M concentrations in spent dialysate for the entire cohort. Optically and laboratory estimated reduction ratio (RR) and total removed solute (TRS) of ß2M were not statistically different (p > 0.35). Dialytic elimination of MM uremic toxin ß2M can be followed optically during dialysis treatment of ESKD patients. The main contributors to the optical signal of the MM fraction in the spent dialysate were provisionally identified as tryptophan (Trp) in small peptides and proteins, and advanced glycation end-products.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Toxinas Biológicas / Uremia / Soluções para Hemodiálise / Microglobulina beta-2 / Diálise Renal / Falência Renal Crônica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Toxins (Basel) Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Toxinas Biológicas / Uremia / Soluções para Hemodiálise / Microglobulina beta-2 / Diálise Renal / Falência Renal Crônica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Toxins (Basel) Ano de publicação: 2021 Tipo de documento: Article