Your browser doesn't support javascript.
loading
SiLiF Neutron Counters to Monitor Nuclear Materials in the MICADO Project.
Cosentino, Luigi; Ducasse, Quentin; Giuffrida, Martina; Lo Meo, Sergio; Longhitano, Fabio; Marchetta, Carmelo; Massara, Antonio; Pappalardo, Alfio; Passaro, Giuseppe; Russo, Salvatore; Finocchiaro, Paolo.
Afiliação
  • Cosentino L; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Ducasse Q; CEA, DES, IRESNE, Nuclear Measurement Laboratory, Cadarache, F-13108 Saint-Paul-lez-Durance, France.
  • Giuffrida M; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Lo Meo S; Centro Siciliano di Fisica Nucleare e Struttura della Materia, 95123 Catania, Italy.
  • Longhitano F; ENEA Centro Ricerche, 40129 Bologna, Italy.
  • Marchetta C; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Massara A; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Pappalardo A; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Passaro G; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Russo S; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
  • Finocchiaro P; INFN Laboratori Nazionali del Sud, 95123 Catania, Italy.
Sensors (Basel) ; 21(8)2021 Apr 08.
Article em En | MEDLINE | ID: mdl-33918061
ABSTRACT
In the framework of the MICADO (Measurement and Instrumentation for Cleaning And Decommissioning Operations) European Union (EU) project, aimed at the full digitization of low- and intermediate-level radioactive waste management, a set of 32 solid state thermal neutron detectors named SiLiF has been built and characterized. MICADO encompasses a complete active and passive characterization of the radwaste drums with neutrons and gamma rays, followed by a longer-term monitoring phase. The SiLiF detectors are suitable for the monitoring of nuclear materials and can be used around radioactive waste drums possibly containing small quantities of actinides, as well as around spent fuel casks in interim storage or during transportation. Suitable polyethylene moderators can be exploited to better shape the detector response to the expected neutron spectrum, according to Monte Carlo simulations that were performed. These detectors were extensively tested with an AmBe neutron source, and the results show a quite uniform and reproducible behavior.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article