Your browser doesn't support javascript.
loading
Single-shot RARE with Dixon: Application to robust abdominal imaging with uniform fat and water separation at 3T.
Wang, Xinzeng; Udayakumar, Durga; Xi, Yin; Rofsky, Neil M; Pedrosa, Ivan; Madhuranthakam, Ananth J.
Afiliação
  • Wang X; Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.
  • Udayakumar D; Global MR Application and Workflow, GE Healthcare, Houston, Texas, USA.
  • Xi Y; Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.
  • Rofsky NM; Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA.
  • Pedrosa I; Department of Radiology, UT Southwestern Medical Center, Dallas, Texas, USA.
  • Madhuranthakam AJ; Population and Data Sciences, UT Southwestern Medical Center, Dallas, Texas, USA.
Magn Reson Med ; 86(3): 1463-1471, 2021 09.
Article em En | MEDLINE | ID: mdl-33929055
ABSTRACT

PURPOSE:

To develop a true single shot turbo spin echo (SShTSE) acquisition with Dixon for robust T2 -weighted abdominal imaging with uniform fat and water separation at 3T.

METHODS:

The in-phase (IP) and out-of-phase (OP) echoes for Dixon processing were acquired in the same repetition time of a SShTSE using partial echoes. A phase-preserved bi-directional homodyne reconstruction was developed to compensate the partial echo and the partial phase encoding of SShTSE. With IRB approval, the SShTSE-Dixon was compared against standard SShTSE, without and with fat suppression using spectral adiabatic inversion recovery (SPAIR) in 5 healthy volunteers and 5 patients. The SNR and contrast ratio (CR) of spleen to liver were compared among different acquisitions.

RESULTS:

The bi-directional homodyne reconstruction successfully minimized ringing artifacts because of partial acquisitions. SShTSE-Dixon achieved uniform fat suppression compared to SShTSE-SPAIR with fat suppression failures of 1/10 versus 10/10 in the axial plane and 0/5 versus 5/5 in the coronal plane, respectively. The SNRs of the liver (12.2 ± 4.9 vs. 11.7 ± 5.2; P = .76) and spleen (25.9 ± 11.6 vs. 23.7 ± 9.7; P = .14) were equivalent between fat-suppressed images (SShTSE-Dixon water-only and SShTSE-SPAIR). The SNRs of liver (14.4 ± 5.7 vs. 13.4 ± 5.0; P = .60) and spleen (26.5 ± 10.1 vs. 25.7 ± 8.5; P = .56) were equivalent between non-fat-suppressed images (SShTSE-Dixon IP and SShTSE). The CRs of spleen to liver were also similar between fat-suppressed images (2.6 ± 0.4 vs. 2.5 ± 0.5; P =.92) and non-fat-suppressed images (2.3 ± 0.6 vs. 2.2 ± 0.4; P =.84).

CONCLUSION:

SShTSE-Dixon generates robust abdominal T2 -weighted images at 3T with and without uniform fat suppression, along with perfectly co-registered fat-only images in a single acquisition.