Your browser doesn't support javascript.
loading
Vagus Nerve Electroneurogram-Based Detection of Acute Pentylenetetrazol Induced Seizures in Rats.
Stumpp, Lars; Smets, Hugo; Vespa, Simone; Cury, Joaquin; Doguet, Pascal; Delbeke, Jean; Nonclercq, Antoine; El Tahry, Riem.
Afiliação
  • Stumpp L; Institute of Neuroscience, Université Catholique de Louvain, Brussels, Belgium.
  • Smets H; BEAMS Department, Université libre de Bruxelles, Brussels, Belgium.
  • Vespa S; Institute of Neuroscience, Université Catholique de Louvain, Brussels, Belgium.
  • Cury J; BEAMS Department, Université libre de Bruxelles, Brussels, Belgium.
  • Doguet P; Synergia Medical SA, Mont-Saint-Guibert, Belgium.
  • Delbeke J; Institute of Neuroscience, Université Catholique de Louvain, Brussels, Belgium.
  • Nonclercq A; BEAMS Department, Université libre de Bruxelles, Brussels, Belgium.
  • El Tahry R; Institute of Neuroscience, Université Catholique de Louvain, Brussels, Belgium.
Int J Neural Syst ; 31(7): 2150024, 2021 Jul.
Article em En | MEDLINE | ID: mdl-34030610
On-demand stimulation improves the efficacy of vagus nerve stimulation (VNS) in refractory epilepsy. The vagus nerve is the main peripheral parasympathetic connection and seizures are known to exhibit autonomic symptoms. Therefore, we hypothesized that seizure detection is possible through vagus nerve electroneurogram (VENG) recording. We developed a metric able to measure abrupt changes in amplitude and frequency of spontaneous vagus nerve action potentials. A classifier was trained using a "leave-one-out" method on a set of 6 seizures and 3 control recordings to utilize the VENG spike feature-based metric for seizure detection. We were able to detect pentylenetetrazol (PTZ) induced acute seizures in 6/6 animals during different stages of the seizure with no false detection. The classifier detected the seizure during an early stage in 3/6 animals and at the onset of tonic clonic stage of the seizure in 3/6 animals. EMG and motion artefacts often accompany epileptic activity. We showed the "epileptic" neural signal to be independent from EMG and motion artefacts. We confirmed the existence of seizure related signals in the VENG recording and proved their applicability for seizure detection. This detection might be a promising tool to improve efficacy of VNS treatment by developing new responsive stimulation systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Epilepsia / Estimulação do Nervo Vago Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Int J Neural Syst Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Epilepsia / Estimulação do Nervo Vago Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Int J Neural Syst Ano de publicação: 2021 Tipo de documento: Article