Your browser doesn't support javascript.
loading
Bright chemiluminescent dioxetane probes for the detection of gaseous transmitter H2S.
Zhang, Zheng; Lin, Yuxing; Li, Zhenzhen; Dong, Gaopan; Gao, Yuqi; Ma, Siyue; Li, Jie; Du, Lupei; Li, Minyong.
Afiliação
  • Zhang Z; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Lin Y; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Li Z; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Dong G; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Gao Y; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Ma S; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Li J; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Du L; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China.
  • Li M; Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (MOE), School of Pharmacy, Shandong University, Jinan, Shandong 250012, China; State Key Laboratory of Microbial Technology, Shandong University, Jinan, Shandong 250100, China. Electronic address: mli@sdu.edu.cn.
Bioorg Med Chem Lett ; 46: 128148, 2021 08 15.
Article em En | MEDLINE | ID: mdl-34058342
ABSTRACT
Hydrogen sulfide (H2S), the third gaseous transmitter after CO and NO, is a double-edged sword in the human body. A specific concentration of H2S can attenuate myocardial ischemia-reperfusion injury by preserving mitochondrial function, in contrast, cause illness, including inflammation and stroke. There are already some probes for the real-time monitoring of the level of H2S in the biological environment. However, they have some disadvantages, such as phototoxicity, low sensitivity, and low quantum yield. In this research, by linking 4-dinitrophenyl-ether (DNP), a specific recognition group for H2S, with a chemiluminophore 1,2-dioxetane, we designed and synthesized the probe SCL-1. To tackle the barrier that the traditional chemiluminescent group has a short emission wavelength and is not easy to penetrate deep tissues, an acrylonitrile electron-withdrawing substituent was installed to the ortho-position of the 1,2-dioxanol hydroxy group. According to the same design strategy as SCL-1, the probe SCL-2 was designed with the modified chemiluminescent group. Studies have shown that SCL-2 with electron-withdrawing acrylonitrile has higher luminescence quantum yield and high sensitivity than SCL-1, realizing real-time detection of H2S in vitro and in vivo. The LOD of SCL-2 was 0.185 µM, which was the best among the currently available luminescent probes for detecting H2S. We envisage that SCL-2 may be a practical toolbox for studying the biological functions of H2S and H2S-related diseases.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corantes Fluorescentes / Compostos Heterocíclicos com 1 Anel / Sulfeto de Hidrogênio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Bioorg Med Chem Lett Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corantes Fluorescentes / Compostos Heterocíclicos com 1 Anel / Sulfeto de Hidrogênio Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Bioorg Med Chem Lett Ano de publicação: 2021 Tipo de documento: Article