Your browser doesn't support javascript.
loading
Simple and efficient spectroscopic-based univariate sequential methods for simultaneous quantitative analysis of vandetanib, dasatinib, and sorafenib in pharmaceutical preparations and biological fluids.
Abdelhameed, Ali S; Hassan, Eman S; Attwa, Mohamed W; Al-Shakliah, Nasser S; Alanazi, Amer M; AlRabiah, Haitham.
Afiliação
  • Abdelhameed AS; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Hassan ES; Department of Medical Laboratory Sciences, Al-Ghad International Medical Sciences College, Female section, P.O. Box 4228, Riyadh 13315, Saudi Arabia.
  • Attwa MW; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia; Students' University Hospital, Mansoura University, Mansoura 35516, Egypt.
  • Al-Shakliah NS; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • Alanazi AM; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.
  • AlRabiah H; Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia. Electronic address: halrabiah@ksu.edu.sa.
Spectrochim Acta A Mol Biomol Spectrosc ; 260: 119987, 2021 Nov 05.
Article em En | MEDLINE | ID: mdl-34082354
ABSTRACT
Six sequential spectrophotometric-based univariate methods were developed and validated for the simultaneous estimation of three novel anticancer drugs vandetanib (VAN), dasatinib (DAS), and sorafenib (SOR) in a mixture, without the requirement for separation. These methods are novel, simple, precise, and accurate. Different steps including zero crossing, ratio-based, and/or derivative spectra were utilized to develop these analytical methods, namely, ratio difference spectrophotometric method, constant center method, successive derivative ratio method, isoabsorptive method, mean centering of the ratio spectra method, and derivative ratio spectrum-zero crossing method. The calibration curve linearity was ranged from 2 to 9, 2-9, and 3-9 µgmL-1 for VAN, DAS, and SOR, respectively. These established methods were applied for the quantification of the three selected drugs in different biological fluids (spiked human plasma and urine) and pharmaceutical preparations. The aforementioned methods were established for the concurrent estimation of ternary and binary mixtures to enhance the signal-to-noise ratio. The results did not statistically differ from the other reported methods, indicating no significant difference in accuracy and precision at p = 0.05.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Preparações Farmacêuticas Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Preparações Farmacêuticas Limite: Humans Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Ano de publicação: 2021 Tipo de documento: Article