Your browser doesn't support javascript.
loading
Improving intensity-modulated radiation therapy quality assurance by adopting statistical process control.
Cui, T; Peng, J-X; Jin, X-L; Chu, X-G; Zhang, J; Cui, L-Z; Xing, X-F.
Afiliação
  • Cui T; Department of Radiotherapy Center, Shanxi Provincial Cancer Hospital, No. 3 of Zhigongxinjie Street, Xinghualing District, Taiyuan, 030000, China.
  • Peng JX; Department of Radiotherapy Center, Shanxi Provincial Cancer Hospital, No. 3 of Zhigongxinjie Street, Xinghualing District, Taiyuan, 030000, China.
  • Jin XL; Department of Cancer Center, Shanxi Bethune Hospital, Taiyuan, 030000, China.
  • Chu XG; Department of Radiotherapy Center, Shanxi Provincial Cancer Hospital, No. 3 of Zhigongxinjie Street, Xinghualing District, Taiyuan, 030000, China.
  • Zhang J; Department of Radiotherapy Center, Shanxi Provincial Cancer Hospital, No. 3 of Zhigongxinjie Street, Xinghualing District, Taiyuan, 030000, China.
  • Cui LZ; Department of Radiotherapy Center, Shanxi Provincial Cancer Hospital, No. 3 of Zhigongxinjie Street, Xinghualing District, Taiyuan, 030000, China.
  • Xing XF; Department of Radiotherapy Center, Shanxi Provincial Cancer Hospital, No. 3 of Zhigongxinjie Street, Xinghualing District, Taiyuan, 030000, China. Electronic address: xing_xiaofen@126.com.
Cancer Radiother ; 26(3): 427-432, 2022 May.
Article em En | MEDLINE | ID: mdl-34090790
ABSTRACT

PURPOSE:

To use statistical process control for intensity-modulated radiation therapy (IMRT) quality assurance (QA) and improve tolerance limits and action limits.

METHODS:

An electronic portal imaging device (EPID) was selected to verify IMRT QA. The I-chart and the exponentially weighted moving averages (EWMA) chart were used to analyze the corresponding results.

RESULTS:

Twenty samples were used to enable the sampling requirements for building the control limits to be met. The I-chart showed that isolated data points beyond the control limits were mainly derived from complex plans. The EWMA made predictions of systematic errors earlier than the I-chart. Systematic errors primarily originated from the dose calibration on the EPID, and recalibrating the EPID could eliminate such errors.

CONCLUSION:

Statistical process control is an effective tool to detect controllable and can be used in IMRT QA. After calibrating the EPID, the tolerance and action limits all improved and satisfied the requirements/recommended values of the AAPM TG-218 report.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada Limite: Humans Idioma: En Revista: Cancer Radiother Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada Limite: Humans Idioma: En Revista: Cancer Radiother Ano de publicação: 2022 Tipo de documento: Article