Your browser doesn't support javascript.
loading
A spectrofluorimetric method for the determination of pindolol in natural waters using various organic and cyclodextrin media.
Gueye, Coumba; Aaron, Jean-Jacques; Gaye-Seye, Mame Diabou; Cisse, Lamine; Oturan, Nihal; Oturan, Mehmet A.
Afiliação
  • Gueye C; Laboratoire Géomatériaux et Environnement (LGE), EA 4119, Université Paris-Est Marne-la-Vallé, 5 Boulevard Descartes, Bâtiment IFI, 77454, Marne-la-Vallée Cedex 2, France.
  • Aaron JJ; Laboratoire de Photochimie et d'Analyse, Département de Chimie, Faculté des Sciences et Techniques, Université Cheikh Anta Diop, Dakar, Senegal.
  • Gaye-Seye MD; Laboratoire Géomatériaux et Environnement (LGE), EA 4119, Université Paris-Est Marne-la-Vallé, 5 Boulevard Descartes, Bâtiment IFI, 77454, Marne-la-Vallée Cedex 2, France. jeanjacquesaaron@yahoo.fr.
  • Cisse L; Laboratoire Géomatériaux et Environnement (LGE), EA 4119, Université Paris-Est Marne-la-Vallé, 5 Boulevard Descartes, Bâtiment IFI, 77454, Marne-la-Vallée Cedex 2, France.
  • Oturan N; Laboratoire de Photochimie et d'Analyse, Département de Chimie, Faculté des Sciences et Techniques, Université Cheikh Anta Diop, Dakar, Senegal.
  • Oturan MA; Laboratoire de Photochimie et d'Analyse, Département de Chimie, Faculté des Sciences et Techniques, Université Cheikh Anta Diop, Dakar, Senegal.
Environ Sci Pollut Res Int ; 28(39): 55029-55040, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34128161
ABSTRACT
A simple, sensitive, and rapid spectrofluorimetric method was developed for the determination of the ß-blocker pindolol. The native fluorescence of pindolol was measured in different organic solvents and in cyclodextrin aqueous media. The highest fluorescence signal was obtained in 2-propanol at λem = 303 nm with λex = 260 nm. Analytical figures of merit for the spectrofluorimetric determination of pindolol were satisfactory, with wide linear dynamic range (LDR) values of two orders of magnitude, and rather low limit of detection (LOD) values between 0.2 and 8.7 ng/mL. Moreover, the addition of cyclodextrins (HP-ß-CD and ß-CD) in aqueous media enhanced the fluorescence of pindolol. In addition, the inclusion complexes of pindolol with cyclodextrins were investigated and the stability constants of complexes were calculated by means of the method of nonlinear regression (NLR). The method was successfully applied to the analysis of tap water and natural water samples, spiked with pindolol.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pindolol / Ciclodextrinas Idioma: En Revista: Environ Sci Pollut Res Int Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pindolol / Ciclodextrinas Idioma: En Revista: Environ Sci Pollut Res Int Ano de publicação: 2021 Tipo de documento: Article