Your browser doesn't support javascript.
loading
Report of AAPM Task Group 219 on independent calculation-based dose/MU verification for IMRT.
Zhu, Timothy C; Stathakis, Sotiris; Clark, Jennifer R; Feng, Wenzheng; Georg, Dietmar; Holmes, Shannon M; Kry, Stephen F; Ma, Chang-Ming Charlie; Miften, Moyed; Mihailidis, Dimitris; Moran, Jean M; Papanikolaou, Niko; Poppe, Bjorn; Xiao, Ying.
Afiliação
  • Zhu TC; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
  • Stathakis S; Department of Radiation Oncology, UTHSCSA, San Antonio, TX, USA.
  • Clark JR; Sun Nuclear Corporation, Melbourne, FL, USA.
  • Feng W; Department of Radiation Oncology, Columbia University, New York, NY, USA.
  • Georg D; Department of Radiation Oncology, Medical University Vienna, Vienna, Austria.
  • Holmes SM; Standard Imaging, Middleton, WI, USA.
  • Kry SF; IROC, UT MD Anderson Cancer Center, Houston, TX, USA.
  • Ma CC; Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA.
  • Miften M; Department of Radiation Oncology, University of Colorado Denver, Aurora, CO, USA.
  • Mihailidis D; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
  • Moran JM; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Papanikolaou N; Department of Radiation Oncology, UTHSCSA, San Antonio, TX, USA.
  • Poppe B; Pius Hospital & Carl von Ossietzky University, Oldenburg, Germany.
  • Xiao Y; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA.
Med Phys ; 48(10): e808-e829, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34213772
Independent verification of the dose per monitor unit (MU) to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance (QA). We discuss the role of secondary dose/MU calculation programs as part of a comprehensive QA program. This report provides guidelines on calculation-based dose/MU verification for intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) provided by various modalities. We provide a review of various algorithms for "independent/second check" of monitor unit calculations for IMRT/VMAT. The report makes recommendations on the clinical implementation of secondary dose/MU calculation programs; on commissioning and acceptance of various commercially available secondary dose/MU calculation programs; on benchmark QA and periodic QA; and on clinically reasonable action levels for agreement of secondary dose/MU calculation programs.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Med Phys Ano de publicação: 2021 Tipo de documento: Article