Your browser doesn't support javascript.
loading
Percutaneous Transgastric Duodenal Stenting and Gastrostomy Repair Using a Vascular Closure Device: Proof of Concept in a Porcine Model.
Shlomovitz, Eran; Patel, Neeral R; Diana, Michele; Pescarus, Radu; Swanström, Lee L.
Afiliação
  • Shlomovitz E; Department of Interventional Radiology, 7989University Health Network, University of Toronto, Toronto, ON, Canada.
  • Patel NR; Department of Surgery, 54809Intitute Hospitalo-Universitaire Strasbourg, Strasbourg, France.
  • Diana M; Department of Interventional Radiology, 7989University Health Network, University of Toronto, Toronto, ON, Canada.
  • Pescarus R; Department of Surgery, 54809Intitute Hospitalo-Universitaire Strasbourg, Strasbourg, France.
  • Swanström LL; Department of Surgery, 67120Hôspital du Sacré-Coeur de Montréal, Université de Montréal, Montreal, QC, Canada.
Surg Innov ; 29(2): 139-144, 2022 Apr.
Article em En | MEDLINE | ID: mdl-34243695
Introduction. Gastroduodenal stenting is efficacious and safe in both benign and malignant foregut diseases. Transgastric duodenal stenting has been described and however requires a gastrostomy tube to remain in situ for 4 to 6 weeks post-procedure which can lead to complications. We present a technique for immediate gastric repair using a suture-mediated vascular closure device, without the need for a gastrostomy tube in porcine models. Methods. Percutaneous access into the stomach was achieved using fluoroscopy. Two or 3 Perclose Proglide devices were pre-deployed. The tract was dilated and a wire advanced into the distal duodenum. A 15.5 cm covered enteric stent was delivered through the gastrostomy, deployed and position confirmed. The gastrostomy was closed using Perclose Proglide sutures. Necropsy leak pressure measurement was performed to assess integrity of gastrostomy closure in the porcine models. Results. Two (n = 8) or 3 (n = 2) Perclose Proglide devices were deployed in ten porcine models, with 1 misfire (4.5%). Percutaneous transgastric access and stent delivery was successful in all porcine models. Mean leak pressure in the animals with adequately deployed devices was 219 mmHg (range 172 mmHg-270 mmHg). Conclusion. This study demonstrates percutaneous transgastric duodenal stenting with immediate gastric repair using suture-mediated vascular closure devices is a feasible procedure.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Oclusão Vascular Limite: Animals Idioma: En Revista: Surg Innov Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Oclusão Vascular Limite: Animals Idioma: En Revista: Surg Innov Ano de publicação: 2022 Tipo de documento: Article